Validation of a handheld ?-hydroxybutyrate acid meter to identify hyperketonaemia in ewes.


ABSTRACT: Background:The end of pregnancy is the period with the highest risk of occurrences of ketosis and pregnancy toxemia due to fat mobilization and increasing non-esterified fatty acids in the liver which are converted in ketone bodies, mainly ?-hydroxybutyrate acid (BHB). This ketone body may also become elevated in the bloodstream. The present study validates the use of a handheld meter for determining the blood concentration of BHB and ascertaining the predictive value and accuracy of BHB measurements in diagnosing hyperketonaemia in ewes. Methods:A total of 19, non-pregnant, crossbred ewes were subjected to 2 h of intravenous infusion of a saturated BHB solution. Over 6 h of evaluation, 247 blood samples were obtained in 13 sampling moments. The BHB concentration was measured by an enzymatic colorimetric method in an automated biochemical analyzer (gold-standard) and by a handheld meter using an electrochemical enzyme technique. Results:There was a high correlation between both methods (r = 0.98; P < 0.001). Considering the blood BHB concentrations range 0.8-1.6 mmol/L for moderate ketosis the handheld meter presented sensitivity and specificity of 0.98 and 0.81, respectively. For severe ketosis (BHB ? 1.6 mmol/L) sensitivity and specificity were 0.99 and 0.75, respectively. Thus, the handheld device can be useful for diagnoses of cases of mild or severe pregnancy toxemia at field conditions.

SUBMITTER: Araujo CASC 

PROVIDER: S-EPMC7153552 | biostudies-literature | 2020

REPOSITORIES: biostudies-literature

altmetric image

Publications


<h4>Background</h4>The end of pregnancy is the period with the highest risk of occurrences of ketosis and pregnancy toxemia due to fat mobilization and increasing non-esterified fatty acids in the liver which are converted in ketone bodies, mainly β-hydroxybutyrate acid (BHB). This ketone body may also become elevated in the bloodstream. The present study validates the use of a handheld meter for determining the blood concentration of BHB and ascertaining the predictive value and accuracy of BHB  ...[more]

Similar Datasets

| S-EPMC6505764 | biostudies-literature
| S-EPMC7807146 | biostudies-literature
| S-EPMC7579833 | biostudies-literature
| S-EPMC7779416 | biostudies-literature
| 2719536 | ecrin-mdr-crc
2020-03-31 | E-MTAB-8017 | biostudies-arrayexpress
| S-EPMC6542293 | biostudies-literature
| S-EPMC8932950 | biostudies-literature
| S-EPMC8564907 | biostudies-literature
| S-EPMC8358161 | biostudies-literature