Project description:With the emerging Zika virus (ZIKV) epidemic, serologic diagnosis relies on a labor-intensive IgM antibody capture enzyme-linked immunosorbent assay (MAC-ELISA) and confirmation by a plaque reduction neutralization test (PRNT). To streamline serologic testing, several commercial assays have been developed. Our aim was to compare the commercial Euroimmun anti-ZIKV IgM and IgG assays to the reference MAC-ELISA and PRNT currently in use. Serum specimens submitted to Public Health Ontario Laboratory, Canada, were tested for IgM and IgG using the Euroimmun assays and the results were compared with those from MAC-ELISA. The PRNT was performed on positive or equivocal specimens using either MAC-ELISA or Euroimmun assays, MAC-ELISA-inconclusive specimens, and a convenience sample of specimens negative by both assays (cohort 1). Another set of specimens selected on the basis of PRNT results was subsequently tested by the Euroimmun assays (cohort 2). MAC-ELISA was positive, equivocal, negative, and inconclusive in 57/223, 15/223, 147/223, and 4/223 specimens, respectively. Among the 76 specimens that were MAC-ELISA positive, equivocal, or inconclusive, 30 (39.5%) were Euroimmun IgM and/or IgG positive or equivocal. Among the 147 MAC-ELISA-negative specimens, 136 (92.5%) were Euroimmun IgM and IgG negative. The sensitivity of the combined Euroimmun IgM/IgG against the PRNT was 83% (cohort 1) and 92% (cohort 2), whereas the specificity was 81% (cohort 1) and 65% (cohort 2). The combined Euroimmun IgM/IgG showed good specificity (92.5%) but suboptimal sensitivity (39.5%) compared with that of the MAC-ELISA. However, the sensitivity of the combined Euroimmun IgM/IgG against the PRNT was significantly higher (83 to 92%). More studies are needed before commercial assays are implemented for routine ZIKV serologic diagnosis.
Project description:There are currently five serologic assays available for detection of anti-Zika virus (ZIKV) IgM-class antibodies with U.S. Food and Drug Administration emergency use authorization. Among these are the Chembio DPP Zika IgM system (DPP Zika ICA; Chembio, Medford, NY), a rapid immunochromatographic assay (ICA), and the InBios ZIKV Detect 2.0 IgM antibody capture enzyme-linked immunosorbent assay (ZIKV 2.0 MAC-ELISA; InBios international, Inc., Seattle, WA), which has replaced the original InBios ZIKV Detect MAC-ELISA. We evaluated performance of these three serologic assays using 72 specimens characterized by plaque reduction neutralization testing (PRNT) for the presence or absence of neutralizing antibodies (NAbs) to ZIKV, dengue virus (DENV), and West Nile virus (WNV). The InBios ZIKV 2.0 MAC-ELISA was "presumptive Zika positive" in all 15 PRNT-confirmed ZIKV samples, while the Chembio DPP Zika ICA was nonreactive in three (20%) and the InBios ZIKV MAC-ELISA was negative in four (27%). The Chembio DPP Zika ICA and InBios ZIKV 2.0 MAC-ELISA showed >95% specificity in 22 ZIKV/DENV-seronegative specimens and in 13 samples positive for NAbs to non-ZIKV flaviviruses. Comparatively, the InBios ZIKV MAC-ELISA was "presumptive" or "possible Zika positive" in 8 of 12 WNV or DENV PRNT-positive samples and in 12 of 22 PRNT-seronegative sera. Our findings suggest that replacement of the InBios ZIKV MAC-ELISA with the InBios ZIKV 2.0 MAC-ELISA will lead to fewer samples requiring PRNT, minimizing unnecessary anxiety among patients ultimately determined to be seronegative for ZIKV and DENV by PRNT and alleviating some of the testing burden on laboratories performing PRNT.
Project description:Enzyme linked immunosorbent assay (ELISA) has now gained wide acclaim in the immunodiagnosis of infectious diseases. ELISA is continuously evolving with newer and sensitive formulations being added to it. The basic tenets of ELISA are discussed. The role of ELISA in two important issues facing us today, namely tuberculosis and human immunodeficiency virus infection are reviewed.
Project description:IntroductionCoronavirus disease 2019 (COVID-19) is caused by Severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2). Fast, accurate, and simple blood-based assays for quantification of anti-SARS-CoV-2 antibodies are urgently needed to identify infected individuals and keep track of the spread of disease.MethodsThe study included 33 plasma samples from 20 individuals with confirmed COVID-19 by real-time reverse-transcriptase polymerase chain reaction and 40 non-COVID-19 plasma samples. Anti-SARS-CoV-2 immunoglobulin M (IgM)/immunoglobulin A (IgA) or immunoglobulin G (IgG) antibodies were detected by a microfluidic quantitative immunomagnetic assay (IMA) (ViroTrack Sero COVID IgM + IgA/IgG Ab, Blusense Diagnostics) and compared to an enzyme-linked immunosorbent assay (ELISA) (EuroImmun Medizinische Labordiagnostika).ResultsOf the 33 plasma samples from the COVID-19 patients, 28 were positive for IgA/IgM or IgG by IMA and 29 samples were positive by ELISA. Sensitivity for only one sample per patient was 68% for IgA + IgM and 75% IgG by IMA and 80% by ELISA. For samples collected 14 days after symptom onset, the sensitivity of both IMA and ELISA was around 91%. The specificity of the IMA reached 100% compared to 95% for ELISA IgA and 97.5% for ELISA IgG.ConclusionIMA for COVID-19 is a rapid simple-to-use point-of-care test with sensitivity and specificity similar to a commercial ELISA.
Project description:Dot blot and transblot enzyme-linked immunosorbent assays (e.l.i.s.a.) are described which provide sensitive non-radioactive methods for screening Z-DNA-specific antisera and for detecting Z-DNA in polydeoxyribonucleotides and supercoiled plasmids. In the alkaline phosphatase dot blot e.l.i.s.a., Z-DNA, Br-poly(dG-dC).poly(dG-dC), or B-DNA, poly(dG-dC).poly(dG-dC), poly(dA-dT).poly(dA-dT), Br-poly(dI-dC).poly(dI-dC), or salmon sperm DNA were spotted onto nitrocellulose discs and baked. The e.l.i.s.a. was conducted in 48-well culture dishes at 37 degrees C using a rabbit polyclonal antiserum developed against Br-poly(dG-dC).poly(dG-dC), an alkaline phosphatase-conjugated second antibody, and p-nitrophenol as the substrate. Under conditions where antibody concentrations were not limiting, alkaline phosphatase activity was linear for 2 h. Dot blot e.l.i.s.a. conditions are described which allow quantification of Z-DNA [Br-poly(dG-dC).poly(dG-dC)] within the range 5-250 ng. Dot blot and transblot horseradish peroxidase e.l.i.s.a. are described that detect Z-DNA within supercoiled plasmid DNAs immobilized on diazophenylthioether (DPT) paper. In the transblot e.l.i.s.a., plasmid pUC8 derivatives containing 16, 24, or 32 residues of Z-DNA were electrophoresed in agarose gels and electrophoretically transferred to DPT paper. Z-DNA-antibody complexes were detected by the horseradish peroxidase-catalysed conversion of 4-chloro-1-naphthol to a coloured product that was covalently bound to the DPT paper. Z-DNA antibody reactivity was specific for supercoiled Z-DNA containing plasmids after removal of the antibodies cross-reactive with B-DNA by absorption onto native DNA-cellulose. The transblot e.l.i.s.a. was sensitive enough to detect 16 base pairs of alternating G-C residues in 100 ng of pUC8 DNA.
Project description:BACKGROUND:Besides SARS-CoV-2 RT-PCR testing, serological testing is emerging as additional option in COVID-19 diagnostics. Aim of this study was to evaluate novel immunoassays for detection of SARS-CoV-2 antibodies in human plasma. METHODS:Using EDITM Novel Coronavirus COVID-19 Enzyme Linked Immunosorbent Assays (ELISAs), we measured SARS-CoV-2 IgM and IgG antibodies in 64 SARS-CoV-2 RT-PCR confirmed COVID-19 patients with serial blood samples (n = 104) collected at different time points from symptom onset. Blood samples from 200 healthy blood donors and 256 intensive care unit (ICU) patients collected before the COVID-19 outbreak were also used. RESULTS:The positivity rates in the COVID-19 patients were 5.9% for IgM and 2.9% for IgG ? 5 days after symptom onset; Between day 5 and day 10 the positivity rates were 37.1% for IgM and 37.1% for IgG and rose to 76.4% for IgM and 82.4% for IgG after > 10-15 days. After 15-22 days the "true" positivity rates were 94.4% for IgM and 100% for IgG. The "false" positivity rates were 0.5% for IgM and 1.0% for IgG in the healthy blood donors, 1.6% for IgM and 1.2% for IgG in ICU patients. CONCLUSIONS:This study shows high "true" vs. low "false" positivity rates for the EDITM SARS-CoV-2 IgM and IgG ELISAs.
Project description:The recent outbreaks of Zika virus (ZIKV) and associated birth defects in regions of dengue virus (DENV) endemicity emphasize the need for sensitive and specific serodiagnostic tests. We reported previously that enzyme-linked immunosorbent assays (ELISAs) based on the nonstructural protein 1 (NS1) of DENV serotype 1 (DENV1) and ZIKV can distinguish primary DENV1, secondary DENV, and ZIKV infections. Whether ELISAs based on NS1 proteins of other DENV serotypes can discriminate various DENV and ZIKV infections remains unknown. We herein developed DENV2, DENV3, and DENV4 NS1 IgG ELISAs to test convalescent- and postconvalescent-phase samples from reverse transcription-PCR-confirmed cases, including 25 primary DENV1, 24 primary DENV2, 10 primary DENV3, 67 secondary DENV, 36 primary West Nile virus, 38 primary ZIKV, and 35 ZIKV with previous DENV infections as well as 55 flavivirus-naive samples. Each ELISA detected primary DENV infection with a sensitivity of 100% for the same serotype and 23.8% to 100% for different serotypes. IgG ELISA using a mixture of DENV1-4 NS1 proteins detected different primary and secondary DENV infections with a sensitivity of 95.6% and specificity of 89.5%. The ZIKV NS1 IgG ELISA detected ZIKV infection with a sensitivity of 100% and specificity of 82.9%. On the basis of the relative optical density ratio, the combination of DENV1-4 and ZIKV NS1 IgG ELISAs distinguished ZIKV with previous DENV and secondary DENV infections with a sensitivity of 91.7% to 94.1% and specificity of 87.0% to 95.0%. These findings have important applications to serodiagnosis, serosurveillance, and monitoring of both DENV and ZIKV infections in regions of endemicity.
Project description:The biological and psychological significance of oxytocin is increasingly recognized; however, reliable assays of oxytocin in biological samples have not been developed. We raised a new oxytocin polyclonal rabbit antibody against synthetic oxytocin. The affinity of antibodies to oxytocin was examined by a radio-immunoassay and compared with that of a previously validated antibody. One antibody showed affinity for oxytocin in the radio-immunoassay. We developed a solid-phase ELISA for oxytocin using this antibody and compared it with existing methods. The newly developed ELISA showed comparable results using urine samples but not using serum samples. These results indicate that the new ELISA is useful for urinary oxytocin; further modifications, such as different extraction methods, are needed for its application to serum oxytocin.
Project description:Zika virus (ZIKV) infection during pregnancy can cause adverse fetal outcomes and severe irreversible congenital birth defects including microcephaly. Immunohistochemistry (IHC) is a valuable diagnostic tool for detecting ZIKV antigens in tissues from cases of fetal loss in women infected with ZIKV, and for providing insights into disease pathogenesis. As a result, there is increasing demand for commercially available ZIKV antibodies for use in IHC assays. ZIKV antibodies were selected and obtained from commercial sources to include both mouse and rabbit hosts, and a variety of antigenic targets. Pretreatment conditions and antibody concentrations resulting in optimal immunohistochemical staining were determined using ZIKV cell control and polymerase chain reaction (PCR)-confirmed ZIKV case control material (fetal brain tissue). Cross-reactivity of the antibodies against other flaviviruses (dengue virus serogroups 1-4, yellow fever virus, Japanese encephalitis virus, West Nile virus) and chikungunya virus was also evaluated. Immunostaining using the commercially available antibodies was compared to a previously validated ZIKV IHC assay used for primary diagnosis. Four antibodies demonstrated optimal staining similar to the previously validated ZIKV IHC assay. Two of the four antibodies cross-reacted with dengue virus, while the other two antibodies showed no cross-reactivity with dengue, other flaviviruses, or chikungunya virus. Differences in the cross-reactivity profiles could not be entirely explained by the antigenic target. Commercially available ZIKV antibodies can be optimized for use in IHC testing to aid in ZIKV diagnostic testing and an evaluation of tissue tropism.
Project description:OBJECTIVE:To establish a non-coated enzyme-linked immunosorbent assay (ELISA) based on zika virus envelope (E) protein for detecting the expression of E protein in infected cells. METHODS:Adherent Vero-143 cells infected with zika virus in a 96-well plate were fixed, and the antibodies against zika virus E protein were added at an optimized concentration to establish the non-coated ELISA method for E protein. The antiviral activities of lignans compound C1 was evaluated using this method. The accuracy of this non-coated ELISA was verified by RT-PCR, and the cross reaction with dengue virus was assessed. RESULTS:After optimization, the background absorbance at 450 nm of uninfected cells was reduced to about 0.20. The antiviral activities of lignans compound C1 detected by this method were basically consistent with the results of RT-PCR. No cross reaction with dengue virus was found in this assay. CONCLUSIONS:A non- coated ELISA method based on zika virus E protein was established, which can be used for screening antiviral agents against zika virus.