Evaluation of the EDI enzyme linked immunosorbent assays for the detection of SARS-CoV-2 IgM and IgG antibodies in human plasma.


ABSTRACT: BACKGROUND:Besides SARS-CoV-2 RT-PCR testing, serological testing is emerging as additional option in COVID-19 diagnostics. Aim of this study was to evaluate novel immunoassays for detection of SARS-CoV-2 antibodies in human plasma. METHODS:Using EDITM Novel Coronavirus COVID-19 Enzyme Linked Immunosorbent Assays (ELISAs), we measured SARS-CoV-2 IgM and IgG antibodies in 64 SARS-CoV-2 RT-PCR confirmed COVID-19 patients with serial blood samples (n = 104) collected at different time points from symptom onset. Blood samples from 200 healthy blood donors and 256 intensive care unit (ICU) patients collected before the COVID-19 outbreak were also used. RESULTS:The positivity rates in the COVID-19 patients were 5.9% for IgM and 2.9% for IgG ? 5 days after symptom onset; Between day 5 and day 10 the positivity rates were 37.1% for IgM and 37.1% for IgG and rose to 76.4% for IgM and 82.4% for IgG after > 10-15 days. After 15-22 days the "true" positivity rates were 94.4% for IgM and 100% for IgG. The "false" positivity rates were 0.5% for IgM and 1.0% for IgG in the healthy blood donors, 1.6% for IgM and 1.2% for IgG in ICU patients. CONCLUSIONS:This study shows high "true" vs. low "false" positivity rates for the EDITM SARS-CoV-2 IgM and IgG ELISAs.

SUBMITTER: Bundschuh C 

PROVIDER: S-EPMC7278646 | biostudies-literature | 2020 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

Evaluation of the EDI enzyme linked immunosorbent assays for the detection of SARS-CoV-2 IgM and IgG antibodies in human plasma.

Bundschuh Christian C   Egger Margot M   Wiesinger Kurt K   Gabriel Christian C   Clodi Martin M   Mueller Thomas T   Dieplinger Benjamin B  

Clinica chimica acta; international journal of clinical chemistry 20200608


<h4>Background</h4>Besides SARS-CoV-2 RT-PCR testing, serological testing is emerging as additional option in COVID-19 diagnostics. Aim of this study was to evaluate novel immunoassays for detection of SARS-CoV-2 antibodies in human plasma.<h4>Methods</h4>Using EDI<sup>TM</sup> Novel Coronavirus COVID-19 Enzyme Linked Immunosorbent Assays (ELISAs), we measured SARS-CoV-2 IgM and IgG antibodies in 64 SARS-CoV-2 RT-PCR confirmed COVID-19 patients with serial blood samples (n = 104) collected at di  ...[more]

Similar Datasets

| S-EPMC7261064 | biostudies-literature
| S-EPMC5527425 | biostudies-literature
| S-EPMC7176053 | biostudies-literature
| S-EPMC5530809 | biostudies-other
| S-EPMC8157164 | biostudies-literature
| S-EPMC3948824 | biostudies-literature
| S-EPMC6425168 | biostudies-literature
| S-EPMC4844749 | biostudies-literature
| S-EPMC1135189 | biostudies-other
| S-EPMC6722596 | biostudies-literature