Unknown

Dataset Information

0

Methodological consensus on clinical proton MRS of the brain: Review and recommendations.


ABSTRACT: Proton MRS (1 H MRS) provides noninvasive, quantitative metabolite profiles of tissue and has been shown to aid the clinical management of several brain diseases. Although most modern clinical MR scanners support MRS capabilities, routine use is largely restricted to specialized centers with good access to MR research support. Widespread adoption has been slow for several reasons, and technical challenges toward obtaining reliable good-quality results have been identified as a contributing factor. Considerable progress has been made by the research community to address many of these challenges, and in this paper a consensus is presented on deficiencies in widely available MRS methodology and validated improvements that are currently in routine use at several clinical research institutions. In particular, the localization error for the PRESS localization sequence was found to be unacceptably high at 3 T, and use of the semi-adiabatic localization by adiabatic selective refocusing sequence is a recommended solution. Incorporation of simulated metabolite basis sets into analysis routines is recommended for reliably capturing the full spectral detail available from short TE acquisitions. In addition, the importance of achieving a highly homogenous static magnetic field (B0 ) in the acquisition region is emphasized, and the limitations of current methods and hardware are discussed. Most recommendations require only software improvements, greatly enhancing the capabilities of clinical MRS on existing hardware. Implementation of these recommendations should strengthen current clinical applications and advance progress toward developing and validating new MRS biomarkers for clinical use.

SUBMITTER: Wilson M 

PROVIDER: S-EPMC7179569 | biostudies-literature | 2019 Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

Methodological consensus on clinical proton MRS of the brain: Review and recommendations.

Wilson Martin M   Andronesi Ovidiu O   Barker Peter B PB   Bartha Robert R   Bizzi Alberto A   Bolan Patrick J PJ   Brindle Kevin M KM   Choi In-Young IY   Cudalbu Cristina C   Dydak Ulrike U   Emir Uzay E UE   Gonzalez Ramon G RG   Gruber Stephan S   Gruetter Rolf R   Gupta Rakesh K RK   Heerschap Arend A   Henning Anke A   Hetherington Hoby P HP   Huppi Petra S PS   Hurd Ralph E RE   Kantarci Kejal K   Kauppinen Risto A RA   Klomp Dennis W J DWJ   Kreis Roland R   Kruiskamp Marijn J MJ   Leach Martin O MO   Lin Alexander P AP   Luijten Peter R PR   Marjańska Małgorzata M   Maudsley Andrew A AA   Meyerhoff Dieter J DJ   Mountford Carolyn E CE   Mullins Paul G PG   Murdoch James B JB   Nelson Sarah J SJ   Noeske Ralph R   Öz Gülin G   Pan Julie W JW   Peet Andrew C AC   Poptani Harish H   Posse Stefan S   Ratai Eva-Maria EM   Salibi Nouha N   Scheenen Tom W J TWJ   Smith Ian C P ICP   Soher Brian J BJ   Tkáč Ivan I   Vigneron Daniel B DB   Howe Franklyn A FA  

Magnetic resonance in medicine 20190328 2


Proton MRS (<sup>1</sup> H MRS) provides noninvasive, quantitative metabolite profiles of tissue and has been shown to aid the clinical management of several brain diseases. Although most modern clinical MR scanners support MRS capabilities, routine use is largely restricted to specialized centers with good access to MR research support. Widespread adoption has been slow for several reasons, and technical challenges toward obtaining reliable good-quality results have been identified as a contrib  ...[more]

Similar Datasets

| S-EPMC7882010 | biostudies-literature
| S-EPMC8569948 | biostudies-literature
| S-EPMC7283031 | biostudies-literature
| S-EPMC4212831 | biostudies-other
| S-EPMC7354897 | biostudies-literature
| S-EPMC6088784 | biostudies-literature
| S-EPMC5612370 | biostudies-literature
| S-EPMC6368663 | biostudies-literature
| S-EPMC9258051 | biostudies-literature
| S-EPMC3847163 | biostudies-literature