Unknown

Dataset Information

0

Cost-Effective Potentiometric Platforms Modified with Multi-Walled Carbon Nanotubes (MWCNTs) and Based on Imprinted Receptors for Fluvoxamine Assessment.


ABSTRACT: A simple, efficient and reliable analytical method was developed and used for the determination of the fluvoxamine drug (FLV) in pharmaceutical preparations and biological fluids. The method is based on the cost-effective screen-printed platform for the potential transduction of the drug. Host-tailored molecular imprinting polymer (MIP) was integrated with the potentiometric platform as a recognition receptor, in which FLV, acrylamide (AAm), ethylene glycol dimethacrylate (EGDMA) and acetonitrile were used as a template, functional monomer, cross-linker, and solvent, respectively. MIP particles were dispersed in plasticized poly (vinyl chloride) (PVC) and the membrane was drop-casted on carbon screen-printed electrode. The MIP, in addition to non-imprinted polymers (NIP), was characterized and the binding experiment revealed high affinity and adsorption capacity of MIP towards FLV. The proposed sensor displayed near-Nernstian cationic slope of 55.0 ± 0.8 mV/decade (r2 = 0.999) with a low detection limit of 4.8 × 10-6 mol/L over a wide pH range (3.0-8.5). The electrochemical features of the proposed sensors including electrochemical impedance spectroscopy (EIS) and chronopotentiometry measurements (CP) in the presence of multi-walled carbon nanotubes (MWCNTs) as a solid contact transducer were also investigated. The applications of the proposed sensor for the determination of FLV in different dosage forms with recovery values (98.8%-101.9%) and (97.4%-101.1%), respectively compared with the reference HPLC method with acceptedFandt-student tests values at the 95% confidence level.

SUBMITTER: Hashem HM 

PROVIDER: S-EPMC7183319 | biostudies-literature | 2020 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

Cost-Effective Potentiometric Platforms Modified with Multi-Walled Carbon Nanotubes (MWCNTs) and Based on Imprinted Receptors for Fluvoxamine Assessment.

Hashem Heba M HM   Hashem Heba M HM   Hassan Saad S M SSM   Kamel Ayman H AH   Amr Abd El-Galil E AEE   AbdelBary E M EM  

Polymers 20200317 3


A simple, efficient and reliable analytical method was developed and used for the determination of the fluvoxamine drug (FLV) in pharmaceutical preparations and biological fluids. The method is based on the cost-effective screen-printed platform for the potential transduction of the drug. Host-tailored molecular imprinting polymer (MIP) was integrated with the potentiometric platform as a recognition receptor, in which FLV, acrylamide (AAm), ethylene glycol dimethacrylate (EGDMA) and acetonitril  ...[more]

Similar Datasets

| S-EPMC5458950 | biostudies-other
| S-EPMC7795803 | biostudies-literature
| S-EPMC3496593 | biostudies-literature
| S-EPMC8431017 | biostudies-literature
| S-EPMC6766930 | biostudies-literature
| S-EPMC5506968 | biostudies-other
| S-EPMC3211174 | biostudies-literature
| S-EPMC4373402 | biostudies-literature
| S-EPMC4090615 | biostudies-literature
| S-EPMC6136419 | biostudies-literature