Effects of DTL electrode position on the amplitude and implicit time of the electroretinogram.


ABSTRACT: PURPOSE:This study sought to investigate whether there is an optimal position of the Dawson, Trick, and Litzkow (DTL) electrodes when measuring the full-field electroretinogram (ERG) for monitoring purposes. METHODS:In 200 uveitis patients, an extended light-adapted (LA) ERG protocol was measured twice, incorporating the International Society for Clinical Electrophysiology of Vision standards. First, a LA ERG was measured with the DTL in the lower lid position (LLP) and thereafter in the fornix position. Differences in amplitudes and implicit times of a-waves, b-waves, and the 30 Hz peak were investigated. Intraclass correlation coefficients (ICCs) as well as coefficients of variation (CoV) were calculated, to assess both reliability and relative variability between the two DTL positions. RESULTS:Implicit times showed no statistically significant differences between the two DTL positions. As expected, amplitudes at the different stimulus strengths were 1.12-1.19 higher in the LLP, but there were no significant differences in the CoV between the two DTL positions. The ICC was high for the b-wave and 30 Hz flicker response (0.842-0.979), but lower for the a-wave, especially for amplitudes (0.584-0.716). CONCLUSIONS:For monitoring purposes in patients, we conclude that based on relative variability, no position is preferable above the other. However, because in most diseases amplitudes are decreased, the LLP may be chosen because it yields higher amplitudes. Whatever the choice, it is important to ensure that the DTL position remains stable during an ERG recording.

SUBMITTER: Brouwer AH 

PROVIDER: S-EPMC7205847 | biostudies-literature | 2020 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

Effects of DTL electrode position on the amplitude and implicit time of the electroretinogram.

Brouwer Anna H AH   de Wit Gerard C GC   de Boer Joke H JH   van Genderen Maria M MM  

Documenta ophthalmologica. Advances in ophthalmology 20191104 3


<h4>Purpose</h4>This study sought to investigate whether there is an optimal position of the Dawson, Trick, and Litzkow (DTL) electrodes when measuring the full-field electroretinogram (ERG) for monitoring purposes.<h4>Methods</h4>In 200 uveitis patients, an extended light-adapted (LA) ERG protocol was measured twice, incorporating the International Society for Clinical Electrophysiology of Vision standards. First, a LA ERG was measured with the DTL in the lower lid position (LLP) and thereafter  ...[more]

Similar Datasets

| S-EPMC5126055 | biostudies-literature
| S-EPMC9101256 | biostudies-literature
| S-EPMC8378545 | biostudies-literature
| S-EPMC7759986 | biostudies-literature
| S-EPMC6314057 | biostudies-literature
| S-EPMC2900654 | biostudies-literature
| S-EPMC9077889 | biostudies-literature
| S-EPMC6161890 | biostudies-literature
| S-EPMC3716878 | biostudies-literature
| S-EPMC4338381 | biostudies-other