Coupling IR-MALDESI with Drift Tube Ion Mobility-Mass Spectrometry for High-Throughput Screening and Imaging Applications.


ABSTRACT: Because of its high degree of selectivity and chemical resolution, mass spectrometry (MS) is rapidly becoming the analytical method of choice for high-throughput evaluations and clinical diagnostics. While advances in MS resolving power have increased by an order of magnitude over the past decade, advances in sample introduction are still needed for high-throughput screening applications where the time frame of chromatographic separation would limit the duty cycle. Infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) is an ambient ionization source that has been shown to be applicable for direct analyses and mass spectrometry imaging (MSI) of complex biological samples in a high-throughput manner. To increase a range of detectable features in IR-MALDESI experiments, we integrated the home-built ion source with a commercially available drift tube ion mobility spectrometer-mass spectrometer (IMS-MS) and analyzed small polar molecules, lipids, carbohydrates, and intact proteins. We also describe in detail how the pulsed ionization source was synchronized with IMS-MS.

SUBMITTER: Ekelof M 

PROVIDER: S-EPMC7263366 | biostudies-literature | 2020 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

Coupling IR-MALDESI with Drift Tube Ion Mobility-Mass Spectrometry for High-Throughput Screening and Imaging Applications.

Ekelöf Måns M   Dodds James J   Khodjaniyazova Sitora S   Garrard Kenneth P KP   Baker Erin S ES   Muddiman David C DC  

Journal of the American Society for Mass Spectrometry 20200211 3


Because of its high degree of selectivity and chemical resolution, mass spectrometry (MS) is rapidly becoming the analytical method of choice for high-throughput evaluations and clinical diagnostics. While advances in MS resolving power have increased by an order of magnitude over the past decade, advances in sample introduction are still needed for high-throughput screening applications where the time frame of chromatographic separation would limit the duty cycle. Infrared matrix-assisted laser  ...[more]

Similar Datasets

| S-EPMC7467419 | biostudies-literature
| S-EPMC5744684 | biostudies-literature
| S-EPMC3633476 | biostudies-literature
| S-EPMC9319919 | biostudies-literature
| S-EPMC4188271 | biostudies-other
| S-EPMC5853271 | biostudies-literature
| S-EPMC6520154 | biostudies-literature
| S-EPMC9269308 | biostudies-literature
| S-EPMC5693761 | biostudies-literature
| S-EPMC2913656 | biostudies-literature