Unknown

Dataset Information

0

Balloon-expandable versus self-expanding transcatheter aortic valve replacement for bioprosthetic dysfunction: A systematic review and meta-analysis.


ABSTRACT: BACKGROUND:Transcatheter aortic valve-in-valve (VIV) procedure is a safe alternative to conventional reoperation for bioprosthetic dysfunction. Balloon-expandable valve (BEV) and self-expanding valve (SEV) are the 2 major types of devices used. Evidence regarding the comparison of the 2 valves remains scarce. METHODS:A systematic review and meta-analysis was conducted to compare the outcomes of BEV and SEV in transcatheter VIV for aortic bioprostheses dysfunction. A computerized search of Medline, PubMed, Embase, and Cochrane databases was performed. English-language journal articles reporting SEV or BEV outcomes of at least 10 patients were included. RESULTS:In total, 27 studies were included, with 2,269 and 1,671 patients in the BEV and SEV groups, respectively. Rates of 30-day mortality and stroke did not differ significantly between the 2 groups. However, BEV was associated with significantly lower rates of postprocedural permanent pacemaker implantation (3.8% vs. 12%; P < 0.001). Regarding echocardiographic parameters, SEV was associated with larger postprocedural effective orifice area at 30 days (1.53 cm2 vs. 1.23 cm2; P < 0.001) and 1 year (1.55 cm2 vs. 1.22 cm2; P < 0.001). CONCLUSIONS:For patients who underwent transcatheter aortic VIV, SEV was associated with larger postprocedural effective orifice area but higher rates of permanent pacemaker implantation. These findings provide valuable information for optimizing device selection for transcatheter aortic VIV.

SUBMITTER: Lee HA 

PROVIDER: S-EPMC7263630 | biostudies-literature | 2020

REPOSITORIES: biostudies-literature

altmetric image

Publications

Balloon-expandable versus self-expanding transcatheter aortic valve replacement for bioprosthetic dysfunction: A systematic review and meta-analysis.

Lee Hsiu-An HA   Chou An-Hsun AH   Wu Victor Chien-Chia VC   Chen Dong-Yi DY   Lee Hsin-Fu HF   Lee Kuang-Tso KT   Chu Pao-Hsien PH   Cheng Yu-Ting YT   Chang Shang-Hung SH   Chen Shao-Wei SW  

PloS one 20200601 6


<h4>Background</h4>Transcatheter aortic valve-in-valve (VIV) procedure is a safe alternative to conventional reoperation for bioprosthetic dysfunction. Balloon-expandable valve (BEV) and self-expanding valve (SEV) are the 2 major types of devices used. Evidence regarding the comparison of the 2 valves remains scarce.<h4>Methods</h4>A systematic review and meta-analysis was conducted to compare the outcomes of BEV and SEV in transcatheter VIV for aortic bioprostheses dysfunction. A computerized s  ...[more]

Similar Datasets

| S-EPMC7925971 | biostudies-literature
| S-EPMC8302989 | biostudies-literature
| S-EPMC4428173 | biostudies-literature
| S-EPMC9270628 | biostudies-literature
| S-EPMC7488327 | biostudies-literature
| S-EPMC8766574 | biostudies-literature
| S-EPMC5137806 | biostudies-literature
| S-EPMC7428568 | biostudies-literature
| S-EPMC5210340 | biostudies-literature
| S-EPMC4959424 | biostudies-literature