Unknown

Dataset Information

0

Comparison of Transcatheter Aortic Valve Replacement between Self-Expanding versus Balloon-Expandable Valves in Patients with Small Aortic Annulus.


ABSTRACT:

Background and objectives

Transcatheter aortic valve replacement (TAVR) has been reported as a good alternative for surgical aortic valve replacement in patients with small aortic annulus. Head-to-head comparisons of different transcatheter aortic valves in these patients are insufficient. We compared the outcomes after TAVR between two different types of recent transcatheter aortic valves (self-expanding vs. balloon-expandable) in patients with small aortic annulus.

Methods

A total of 70 patients with severe aortic stenosis and small annulus (mean diameter ?23 mm or minimal diameter ?21 mm on computed tomography) underwent TAVR with either a self-expanding valve with supra-annular location (n=45) or a balloon-expandable valve with intra-annular location (n=25). The echocardiographic hemodynamic parameters after TAVR and 1-year follow-up were compared.

Results

Between the self-expanding and balloon-expandable valve-treated patients, the clinical outcomes including permanent pacemaker implantation (11.1% vs. 8.0%), acute kidney injury stage 2 or 3 (4.4% vs. 4.0%), and major vascular complication (4.4% vs. 0.0%) were similar without all-cause mortality, stroke, and life-threatening bleeding during 30-day follow-up. Compared with the balloon-expandable valve-treated patients, the self-expanding valve-treated patients presented larger effective orifice area (EOA) (1.46±0.28 vs. 1.75±0.42 cm², p=0.002) and indexed EOA (0.95±0.21 vs. 1.18±0.28 cm²/m², p=0.001), whereas mean aortic valve gradient (11.7±2.9 vs. 8.9±5.2 mmHg, P=0.005) and incidence of ?moderate prosthesis-patient mismatch (36.0% vs. 8.9%, p=0.009) were lower. These hemodynamic differences were maintained at 1-year follow-up.

Conclusions

TAVR with self-expanding valves was associated with superior hemodynamic outcomes compared with balloon-expandable valves in patients with small aortic annulus.

SUBMITTER: Lee YJ 

PROVIDER: S-EPMC7925971 | biostudies-literature | 2021 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

Comparison of Transcatheter Aortic Valve Replacement between Self-Expanding versus Balloon-Expandable Valves in Patients with Small Aortic Annulus.

Lee Yong Joon YJ   Lee Seung Jun SJ   Hong Sung Jin SJ   Shim Chi Young CY   Ahn Chul Min CM   Kim Jung Sun JS   Kim Byeong Keuk BK   Hong Geu Ru GR   Ko Young Guk YG   Choi Donghoon D   Jang Yangsoo Y   Hong Myeong Ki MK  

Korean circulation journal 20210301 3


<h4>Background and objectives</h4>Transcatheter aortic valve replacement (TAVR) has been reported as a good alternative for surgical aortic valve replacement in patients with small aortic annulus. Head-to-head comparisons of different transcatheter aortic valves in these patients are insufficient. We compared the outcomes after TAVR between two different types of recent transcatheter aortic valves (self-expanding vs. balloon-expandable) in patients with small aortic annulus.<h4>Methods</h4>A tot  ...[more]

Similar Datasets

| S-EPMC11308705 | biostudies-literature
| S-EPMC8848425 | biostudies-literature
| S-EPMC7263630 | biostudies-literature
| S-EPMC9390782 | biostudies-literature
| S-EPMC9743542 | biostudies-literature
| S-EPMC8302989 | biostudies-literature
| S-EPMC10586953 | biostudies-literature
| S-EPMC8432462 | biostudies-literature
| S-EPMC11307958 | biostudies-literature
| S-EPMC4428173 | biostudies-literature