Noninvasive, wearable, and tunable electromagnetic multisensing system for continuous glucose monitoring, mimicking vasculature anatomy.


ABSTRACT: Painless, needle-free, and continuous glucose monitoring sensors are needed to enhance the life quality of diabetic patients. To that extent, we propose a first-of-its-kind, highly sensitive, noninvasive continuous glycemic monitoring wearable multisensor system. The proposed sensors are validated on serum, animal tissues, and animal models of diabetes and in a clinical setting. The noninvasive measurement results during human trials reported high correlation (>0.9) between the system's physical parameters and blood glucose levels, without any time lag. The accurate real-time responses of the sensors are attributed to their unique vasculature anatomy-inspired tunable electromagnetic topologies. These wearable apparels wirelessly sense hypo- to hyperglycemic variations with high fidelity. These components are designed to simultaneously target multiple body locations, which opens the door for the development of a closed-loop artificial pancreas.

SUBMITTER: Hanna J 

PROVIDER: S-EPMC7286677 | biostudies-literature | 2020 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

Noninvasive, wearable, and tunable electromagnetic multisensing system for continuous glucose monitoring, mimicking vasculature anatomy.

Hanna Jessica J   Bteich Moussa M   Tawk Youssef Y   Ramadan Ali H AH   Dia Batoul B   Asadallah Fatima A FA   Eid Aline A   Kanj Rouwaida R   Costantine Joseph J   Eid Assaad A AA  

Science advances 20200610 24


Painless, needle-free, and continuous glucose monitoring sensors are needed to enhance the life quality of diabetic patients. To that extent, we propose a first-of-its-kind, highly sensitive, noninvasive continuous glycemic monitoring wearable multisensor system. The proposed sensors are validated on serum, animal tissues, and animal models of diabetes and in a clinical setting. The noninvasive measurement results during human trials reported high correlation (>0.9) between the system's physical  ...[more]

Similar Datasets

| S-EPMC6107296 | biostudies-literature
| S-EPMC6906081 | biostudies-literature
| S-EPMC6432312 | biostudies-literature
| S-EPMC5627266 | biostudies-other
| S-EPMC7431025 | biostudies-literature
| 71713 | ecrin-mdr-crc
| S-EPMC7736301 | biostudies-literature
| S-EPMC2997158 | biostudies-literature
| S-EPMC8730602 | biostudies-literature
| S-EPMC5813454 | biostudies-other