Unknown

Dataset Information

0

Response Surface Methodology As a New Approach for Finding Optimal MALDI Matrix Spraying Parameters for Mass Spectrometry Imaging.


ABSTRACT: Automated spraying devices have become ubiquitous in laboratories employing matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI), in part because they permit control of a number of matrix application parameters that can easily be reproduced for intra- and interlaboratory studies. Determining the optimal parameters for MALDI matrix application, such as temperature, flow rate, spraying velocity, number of spraying cycles, and solvent composition for matrix application, is critical for obtaining high-quality MALDI-MSI data. However, there are no established approaches for optimizing these multiple parameters simultaneously. Instead optimization is performed iteratively (i.e., one parameter at a time), which is time-consuming and can lead to overall nonoptimal settings. In this report, we demonstrate the use a novel experimental design and the response surface methodology to optimize five parameters of MALDI matrix application using a robotic sprayer. Thirty-two combinations of MALDI matrix spraying conditions were tested, which allowed us to elucidate relationships between each of the application parameters as determined by MALDI-MS (specifically, using a 15 T Fourier transform ion cyclotron resonance mass spectrometer). As such, we were able to determine the optimal automated spraying parameters that minimized signal delocalization and enabled high MALDI sensitivity. We envision this optimization strategy can be utilized for other matrix application approaches and MALDI-MSI analyses of other molecular classes and tissue types.

SUBMITTER: Velickovic D 

PROVIDER: S-EPMC7293970 | biostudies-literature | 2020 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

Response Surface Methodology As a New Approach for Finding Optimal MALDI Matrix Spraying Parameters for Mass Spectrometry Imaging.

Veličković Dušan D   Zhang Guanshi G   Bezbradica Dejan D   Bhattacharjee Arunima A   Paša-Tolić Ljiljana L   Sharma Kumar K   Alexandrov Theodore T   Anderton Christopher R CR  

Journal of the American Society for Mass Spectrometry 20200206 3


Automated spraying devices have become ubiquitous in laboratories employing matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI), in part because they permit control of a number of matrix application parameters that can easily be reproduced for intra- and interlaboratory studies. Determining the optimal parameters for MALDI matrix application, such as temperature, flow rate, spraying velocity, number of spraying cycles, and solvent composition for matrix application,  ...[more]

Similar Datasets

| S-EPMC4607658 | biostudies-literature
2024-10-09 | GSE279139 | GEO
| S-EPMC5512960 | biostudies-other
| S-EPMC6730639 | biostudies-literature
| S-EPMC7383219 | biostudies-literature
2018-10-04 | GSE112623 | GEO
| S-EPMC2981679 | biostudies-other
| S-EPMC3324511 | biostudies-other
| S-EPMC6609678 | biostudies-other
| S-EPMC6021752 | biostudies-literature