Low Flow Voltage Free Interface for Capillary Electrophoresis and Mass Spectrometry Driven by Vibrating Sharp-Edge Spray Ionization.


ABSTRACT: Capillary electrophoresis-mass spectrometry is a powerful technique for high-throughput and high efficiency separations combined with structural identification. Electrospray ionization is the primary interface used to couple capillary electrophoresis to mass analyzers; however, improved designs continue to be reported. A new interfacing method based on vibrating sharp-edge spray ionization is presented in this work to overcome the challenges of decoupling applied voltages and to enhance the compatibility with separations performed at near-neutral pH. The versatility and ease of use of this ionization source is demonstrated using ?-blockers, peptides, and proteins. The cationic ?-blocker pindolol was injected electrokinetically, and detected at concentrations ranging from 10 nM to 5 ?M, with an estimated detection limit of 2 nM. The vibrating sharp-edge spray ionization functions with flow rates from 70 to 200 nL/min and did not perturb the capillary electrophoresis separation electroosmotic flow as evidenced by the observation that most migration times differed less than 7% (n = 3) across a lab-built system interfaced to mass spectrometry and a commercial system that utilizes absorbance detection. For cationic beta-blockers the theoretical plates achieved in the capillary electrophoresis-mass spectrometry setup were 80%-95% of that observed with a commercial capillary electrophoresis-UV absorbance detection system.

SUBMITTER: Kristoff CJ 

PROVIDER: S-EPMC7295075 | biostudies-literature | 2020 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications

Low Flow Voltage Free Interface for Capillary Electrophoresis and Mass Spectrometry Driven by Vibrating Sharp-Edge Spray Ionization.

Kristoff Courtney J CJ   Li Chong C   Li Peng P   Holland Lisa A LA  

Analytical chemistry 20200207 4


Capillary electrophoresis-mass spectrometry is a powerful technique for high-throughput and high efficiency separations combined with structural identification. Electrospray ionization is the primary interface used to couple capillary electrophoresis to mass analyzers; however, improved designs continue to be reported. A new interfacing method based on vibrating sharp-edge spray ionization is presented in this work to overcome the challenges of decoupling applied voltages and to enhance the comp  ...[more]

Similar Datasets

| S-EPMC6560627 | biostudies-literature
| S-EPMC8130659 | biostudies-literature
| S-EPMC6529299 | biostudies-literature
| S-EPMC7318871 | biostudies-literature
| S-EPMC8132193 | biostudies-literature
| S-EPMC8296548 | biostudies-literature
| S-EPMC8323477 | biostudies-literature
| S-EPMC4470751 | biostudies-literature
| S-EPMC7695695 | biostudies-literature
| S-EPMC9850406 | biostudies-literature