Unknown

Dataset Information

0

Facile Improvement of Negative Ion Mode Electrospray Ionization Using Capillary Vibrating Sharp-Edge Spray Ionization.


ABSTRACT: Electrospray ionization (ESI) is often affected by corona discharge when spraying 100% aqueous solutions as the voltage that induces discharge can be well below the onset voltage of ESI. As a result, it is especially challenging to perform native mass spectrometry in negative ion mode where 100% aqueous solution is preferred. Here we report a simple instrumentation method to improve the performance of ESI in negative ion mode based on capillary vibrating sharp-edge spray ionization. By attaching a fused silica capillary emitter to a vibrating glass slide, improved signal quality is achieved for various analytes in aqueous solutions over applying ESI alone. Compared to commercial ESI sources using nebulization gas to reduce discharge, 10-100-fold enhancement in signal intensity and 3-10-fold improvement in S/N are achieved for various kinds of molecules including DNA, peptides, proteins, and oligosaccharides. Finally, the new method demonstrates utility for native mass spectrometry analysis of proteins and G-quadruplex DNA. The present method is expected to have great potential to be adopted by the scientific community because of its improved analytical performance, simplicity, and low cost.

SUBMITTER: Li C 

PROVIDER: S-EPMC7318871 | biostudies-literature | 2020 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications

Facile Improvement of Negative Ion Mode Electrospray Ionization Using Capillary Vibrating Sharp-Edge Spray Ionization.

Li Chong C   Attanayake Kushani K   Valentine Stephen J SJ   Li Peng P  

Analytical chemistry 20200115 3


Electrospray ionization (ESI) is often affected by corona discharge when spraying 100% aqueous solutions as the voltage that induces discharge can be well below the onset voltage of ESI. As a result, it is especially challenging to perform native mass spectrometry in negative ion mode where 100% aqueous solution is preferred. Here we report a simple instrumentation method to improve the performance of ESI in negative ion mode based on capillary vibrating sharp-edge spray ionization. By attaching  ...[more]

Similar Datasets

| S-EPMC8130659 | biostudies-literature
| S-EPMC6560627 | biostudies-literature
| S-EPMC7295075 | biostudies-literature
| S-EPMC8296548 | biostudies-literature
| S-EPMC8132193 | biostudies-literature
| S-EPMC6529299 | biostudies-literature
| S-EPMC4470751 | biostudies-literature
| S-EPMC7558432 | biostudies-literature
| S-EPMC2861838 | biostudies-literature
| S-EPMC7695695 | biostudies-literature