Unknown

Dataset Information

0

Adaptive radiotherapy and the dosimetric impact of inter- and intrafractional motion on the planning target volume for prostate cancer patients.


ABSTRACT: PURPOSE:To investigate the dosimetric influence of daily interfractional (inter) setup errors and intrafractional (intra) target motion on the planning target volume (PTV) and the possibility of an offline adaptive radiotherapy (ART) method to correct larger patient positioning uncertainties in image-guided radiotherapy for prostate cancer (PCa). MATERIALS AND METHODS:A CTV (clinical target volume)-to-PTV margin ranging from 15?mm in LR (left-right) and SI (superior-inferior) and 5-10?mm in AP (anterior-posterior) direction was applied to all patients. The dosimetric influence of this margin was retrospectively calculated by analysing systematic and random components of inter and intra errors of 31 consecutive intermediate- and high-risk localized PCa patients using daily cone beam computed tomography and kV/kV (kilo-Voltage) imaging. For each patient inter variation was assessed by observing the first 4 treatment days, which led to an offline ART-based treatment plan in case of larger variations. RESULTS:Systematic inter uncertainties were larger (1.12 in LR, 2.28 in SI and 1.48?mm in AP) than intra systematic errors (0.44 in LR, 0.69 in SI and 0.80?mm in AP). Same findings for the random error in SI direction with 3.19 (inter) and 2.30?mm (intra), whereas in LR and AP results were alike with 1.89 (inter) and 1.91?mm (intra) and 2.10 (inter) and 2.27?mm (intra), respectively. The calculated margin revealed dimensions of 4-5?mm in LR, 8-9?mm in SI and 6-7?mm in AP direction. Treatment plans which had to be adapted showed smaller variations with 1.12 (LR) and 1.72?mm (SI) for ? and 4.17 (LR) and 3.75?mm (SI) for ? compared to initial plans with 1.77 and 2.62?mm for ? and 4.46 and 5.39?mm for ? in LR and SI, respectively. CONCLUSION:The currently clinically used margin of 15?mm in LR and SI and 5-10?mm in AP direction includes inter and intra uncertainties. The results show that offline ART is feasible which becomes a necessity with further reductions in PTV margins.

SUBMITTER: Bockelmann F 

PROVIDER: S-EPMC7305089 | biostudies-literature | 2020 Jul

REPOSITORIES: biostudies-literature

altmetric image

Publications

Adaptive radiotherapy and the dosimetric impact of inter- and intrafractional motion on the planning target volume for prostate cancer patients.

Böckelmann Felix F   Putz Florian F   Kallis Karoline K   Lettmaier Sebastian S   Fietkau Rainer R   Bert Christoph C  

Strahlentherapie und Onkologie : Organ der Deutschen Rontgengesellschaft ... [et al] 20200310 7


<h4>Purpose</h4>To investigate the dosimetric influence of daily interfractional (inter) setup errors and intrafractional (intra) target motion on the planning target volume (PTV) and the possibility of an offline adaptive radiotherapy (ART) method to correct larger patient positioning uncertainties in image-guided radiotherapy for prostate cancer (PCa).<h4>Materials and methods</h4>A CTV (clinical target volume)-to-PTV margin ranging from 15 mm in LR (left-right) and SI (superior-inferior) and  ...[more]

Similar Datasets

| S-EPMC8502906 | biostudies-literature
| S-EPMC7948894 | biostudies-literature
| 2165985 | ecrin-mdr-crc
| S-EPMC8474766 | biostudies-literature
| S-EPMC10570575 | biostudies-literature
| S-EPMC7477222 | biostudies-literature
| S-EPMC7807636 | biostudies-literature
| S-EPMC4499938 | biostudies-literature
| S-EPMC7807863 | biostudies-literature
| S-EPMC7807634 | biostudies-literature