Unknown

Dataset Information

0

Plasmonic/magnetic molybdenum trioxide and graphitic carbon nitride quantum dots-based fluoroimmunosensing system for influenza virus.


ABSTRACT: A novel magnetic/plasmonic-assisted fluoro-immunoassay system is developed for the detection of influenza virus using magnetic-derivatized plasmonic molybdenum trioxide quantum dots (MP-MoO3 QDs) as the plasmonic/magnetic agent and fluorescent graphitic carbon nitride quantum dots (gCNQDs) as the monitoring probe. Specific antibody against influenza A virus was conjugated onto the surface of MP-MoO3 QDs and gCNQDs, respectively. In the presence of influenza A virus (as the test virus), a core-satellite immunocomplex is formed between the antibody-conjugated nanomaterials (Ab-MP-MoO3 QDs and Ab-gCNQDs) and their interaction resulted in the modulation and gradual enhancement of the fluorescence intensity of the detection probe with the influenza virus concentration-dependent increase. In addition, PL change without influenza A virus was not observed. Limits of detection of 0.25 and 0.9?pg/mL were achieved for Influenza virus A/New Caledonia (20/99/IVR/116) (H1N1) detection in deionized water and human serum, respectively. Clinically isolated influenza virus A/Yokohama (110/2009) (H3N2) was detected in the range of 45 - 25,000 PFU/mL, with a limit of detection ca 45 PFU/mL (as opposed to a minimum of 5000 PFU/mL for a commercial test kit). This developed biosensor provides a robust, sensitive as well as a selective platform for influenza virus detection.

SUBMITTER: Achadu OJ 

PROVIDER: S-EPMC7313904 | biostudies-literature | 2020 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

Plasmonic/magnetic molybdenum trioxide and graphitic carbon nitride quantum dots-based fluoroimmunosensing system for influenza virus.

Achadu Ojodomo J OJ   Takemura Kenshin K   Khoris Indra Memdi IM   Park Enoch Y EY  

Sensors and actuators. B, Chemical 20200622


A novel magnetic/plasmonic-assisted fluoro-immunoassay system is developed for the detection of influenza virus using magnetic-derivatized plasmonic molybdenum trioxide quantum dots (MP-MoO<sub>3</sub> QDs) as the plasmonic/magnetic agent and fluorescent graphitic carbon nitride quantum dots (gCNQDs) as the monitoring probe. Specific antibody against influenza A virus was conjugated onto the surface of MP-MoO<sub>3</sub> QDs and gCNQDs, respectively. In the presence of influenza A virus (as the  ...[more]

Similar Datasets

| S-EPMC7036787 | biostudies-literature
| S-EPMC7756390 | biostudies-literature
| S-EPMC2773548 | biostudies-literature
| S-EPMC7770733 | biostudies-literature
| S-EPMC7559342 | biostudies-literature
| S-EPMC9043259 | biostudies-literature
| S-EPMC8240452 | biostudies-literature
| S-EPMC8395659 | biostudies-literature
| S-EPMC7770884 | biostudies-literature
| S-EPMC6836200 | biostudies-literature