Fast and sensitive flow-injection mass spectrometry metabolomics by analyzing sample-specific ion distributions.


ABSTRACT: Mass spectrometry based metabolomics is a widely used approach in biomedical research. However, current methods coupling mass spectrometry with chromatography are time-consuming and not suitable for high-throughput analysis of thousands of samples. An alternative approach is flow-injection mass spectrometry (FI-MS) in which samples are directly injected to the ionization source. Here, we show that the sensitivity of Orbitrap FI-MS metabolomics methods is limited by ion competition effect. We describe an approach for overcoming this effect by analyzing the distribution of ion m/z values and computationally determining a series of optimal scan ranges. This enables reproducible detection of ~9,000 and ~10,000 m/z features in metabolomics and lipidomics analysis of serum samples, respectively, with a sample scan time of ~15?s and duty time of ~30?s; a ~50% increase versus current spectral-stitching FI-MS. This approach facilitates high-throughput metabolomics for a variety of applications, including biomarker discovery and functional genomics screens.

SUBMITTER: Sarvin B 

PROVIDER: S-EPMC7314751 | biostudies-literature | 2020 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

Fast and sensitive flow-injection mass spectrometry metabolomics by analyzing sample-specific ion distributions.

Sarvin Boris B   Lagziel Shoval S   Sarvin Nikita N   Mukha Dzmitry D   Kumar Praveen P   Aizenshtein Elina E   Shlomi Tomer T  

Nature communications 20200624 1


Mass spectrometry based metabolomics is a widely used approach in biomedical research. However, current methods coupling mass spectrometry with chromatography are time-consuming and not suitable for high-throughput analysis of thousands of samples. An alternative approach is flow-injection mass spectrometry (FI-MS) in which samples are directly injected to the ionization source. Here, we show that the sensitivity of Orbitrap FI-MS metabolomics methods is limited by ion competition effect. We des  ...[more]

Similar Datasets

2020-05-17 | ST001380 | MetabolomicsWorkbench
| S-EPMC5764703 | biostudies-literature
| S-EPMC4081102 | biostudies-literature
| S-EPMC4344516 | biostudies-literature
| S-EPMC7255388 | biostudies-literature
| S-EPMC5757879 | biostudies-literature
| S-EPMC6017308 | biostudies-literature
| S-EPMC4280789 | biostudies-literature
| S-EPMC11351437 | biostudies-literature
| S-EPMC5942887 | biostudies-literature