A portable and high-sensitivity optical sensing system for detecting fluorescently labeled enterohaemorrhagic Escherichia coli Shiga toxin 2B-subunit.


ABSTRACT: We developed a stand-alone, real-time optical detection device capable of reading fluorescence intensities from cell samples with high sensitivity and precision, for use as a portable fluorescent sensor for sensing fluorescently labeled enterohemorrhagic Escherichia coli (EHEC) Shiga toxins (Stxs). In general, the signal intensity from the fluorescently labeled Stxs was weak due to the small number of molecules bound to each cell. To address this technical challenge, we used a highly sensitive light detector (photomultiplier tube: PMT) to measure fluorescence, and designed a portable optical housing to align optical parts precisely; the housing itself was fabricated on a 3D printer. In addition, an electric circuit that amplified PMT output was designed and integrated into the system. The system shows the toxin concentration in the sample on a liquid crystal display (LCD), and a microcontroller circuit is used to read PMT output, process data, and display results. In contrast to other portable fluorescent detectors, the system works alone, without any peripheral computer or additional apparatus; its total size is about 17 × 13 × 9 cm3, and it weighs about 770 g. The detection limit was 0.01 ppm of Alexa Fluor 488 in PBS, which is ten thousand times lower than those of other smartphone-based systems and sufficiently sensitive for use with a portable optical detector. We used the portable real-time optical sensing system to detect Alexa Fluor 488-tagged Stx2B-subunits bound to monocytic THP-1 cells expressing the toxin receptor globotriaosylceramide (Gb3). The device did not detect a signal from Gb3-negative PD36 cells, indicating that it was capable of specifically detecting Stxs bound to cells expressing the toxin receptor. Following the development of a rapid and autonomous method for fluorescently tagging cells in food samples, the optical detection system described here could be used for direct detection of Shiga toxins in food in the field.

SUBMITTER: Kim J 

PROVIDER: S-EPMC7365435 | biostudies-literature | 2020

REPOSITORIES: biostudies-literature

altmetric image

Publications

A portable and high-sensitivity optical sensing system for detecting fluorescently labeled enterohaemorrhagic Escherichia coli Shiga toxin 2B-subunit.

Kim Jeongtae J   Park Jun-Young JY   Park Young-Jun YJ   Park Seo-Young SY   Lee Moo-Seung MS   Koo Chiwan C  

PloS one 20200716 7


We developed a stand-alone, real-time optical detection device capable of reading fluorescence intensities from cell samples with high sensitivity and precision, for use as a portable fluorescent sensor for sensing fluorescently labeled enterohemorrhagic Escherichia coli (EHEC) Shiga toxins (Stxs). In general, the signal intensity from the fluorescently labeled Stxs was weak due to the small number of molecules bound to each cell. To address this technical challenge, we used a highly sensitive l  ...[more]

Similar Datasets

| S-EPMC2238053 | biostudies-literature
| S-EPMC4693993 | biostudies-literature
| S-EPMC8443680 | biostudies-literature
| S-EPMC6049086 | biostudies-literature
| S-EPMC4476919 | biostudies-literature
| S-EPMC6300195 | biostudies-literature
| S-EPMC3535872 | biostudies-literature
| S-EPMC3232646 | biostudies-literature
| S-EPMC3288116 | biostudies-literature
| S-EPMC6492301 | biostudies-literature