Unknown

Dataset Information

0

Selective solvent filters for non-aqueous phase liquid separation from water.


ABSTRACT: Injectable filters permeable to water but impermeable to non-polar solvents were developed to contain non-aqueous phase liquids (NAPL) in contaminated aquifers, hence protecting downstream receptors during NAPL remediation. Filters were produced by injecting aqueous solutions of 0.01% chitosan, hydroxyethylcellulose and quaternized hydroxyethylcellulose into sand columns, followed by rinsing with water. Polymer sorption onto silica was verified using a quartz-crystal microbalance with dissipation monitoring. Fluorescence and gas chromatography mass spectroscopy showed low ppm range concentrations of non-polar solvents (e.g., hexane and toluene) in water eluted from the filters (in the absence of emulsifiers). The contact angles between polymer-coated surfaces and hexane or toluene were >?90°, indicating surface oleophobicity. Organic, polar solvents (e.g. tetrahydrofuran and tetrachloroethylene, TCE) were not separated from water. The contact angles between polymer-coated surfaces and TCE was also?>?90°. However, the contact area with polymer coated surfaces was greater for TCE than non-polar solvents, suggesting higher affinity between TCE and the surfaces. Emulsifiers can be used to facilitate NAPL extraction from aquifers. Emulsion separation efficiency depended on the emulsifier used. Emulsions were not separated with classical surfactants (e.g. Tween 20 and oleic acid) or alkaline zein solutions. Partial emulsion separation was achieved with humic acids and zein particles.

SUBMITTER: Marshall T 

PROVIDER: S-EPMC7371871 | biostudies-literature | 2020 Jul

REPOSITORIES: biostudies-literature

altmetric image

Publications

Selective solvent filters for non-aqueous phase liquid separation from water.

Marshall Tatianna T   Estepa Klaudine M KM   Corradini Maria M   Marangoni Alejandro G AG   Sleep Brent B   Pensini Erica E  

Scientific reports 20200720 1


Injectable filters permeable to water but impermeable to non-polar solvents were developed to contain non-aqueous phase liquids (NAPL) in contaminated aquifers, hence protecting downstream receptors during NAPL remediation. Filters were produced by injecting aqueous solutions of 0.01% chitosan, hydroxyethylcellulose and quaternized hydroxyethylcellulose into sand columns, followed by rinsing with water. Polymer sorption onto silica was verified using a quartz-crystal microbalance with dissipatio  ...[more]

Similar Datasets

| S-EPMC4585788 | biostudies-literature
| S-EPMC6523547 | biostudies-literature
| S-EPMC5980754 | biostudies-literature
| S-EPMC6010786 | biostudies-literature
2021-12-23 | GSE174575 | GEO
| S-EPMC4838917 | biostudies-literature
| S-EPMC7754443 | biostudies-literature
| S-EPMC9290313 | biostudies-literature
| S-EPMC9883474 | biostudies-literature
| S-EPMC6700279 | biostudies-literature