Unknown

Dataset Information

0

Three-dimensional bright-field microscopy with isotropic resolution based on multi-view acquisition and image fusion reconstruction.


ABSTRACT: Optical Projection Tomography (OPT) is a powerful three-dimensional imaging technique used for the observation of millimeter-scaled biological samples, compatible with bright-field and fluorescence contrast. OPT is affected by spatially variant artifacts caused by the fact that light diffraction is not taken into account by the straight-light propagation models used for reconstruction. These artifacts hinder high-resolution imaging with OPT. In this work we show that, by using a multiview imaging approach, a 3D reconstruction of the bright-field contrast can be obtained without the diffraction artifacts typical of OPT, drastically reducing the amount of acquired data, compared to previously reported approaches. The method, purely based on bright-field contrast of the unstained sample, provides a comprehensive picture of the sample anatomy, as demonstrated in vivo on Arabidopsis thaliana and zebrafish embryos. Furthermore, this bright-field reconstruction can be implemented on practically any multi-view light-sheet fluorescence microscope without complex hardware modifications or calibrations, complementing the fluorescence information with tissue anatomy.

SUBMITTER: Calisesi G 

PROVIDER: S-EPMC7392767 | biostudies-literature | 2020 Jul

REPOSITORIES: biostudies-literature

altmetric image

Publications

Three-dimensional bright-field microscopy with isotropic resolution based on multi-view acquisition and image fusion reconstruction.

Calisesi Gianmaria G   Candeo Alessia A   Farina Andrea A   D'Andrea Cosimo C   Magni Vittorio V   Valentini Gianluca G   Pistocchi Anna A   Costa Alex A   Bassi Andrea A  

Scientific reports 20200729 1


Optical Projection Tomography (OPT) is a powerful three-dimensional imaging technique used for the observation of millimeter-scaled biological samples, compatible with bright-field and fluorescence contrast. OPT is affected by spatially variant artifacts caused by the fact that light diffraction is not taken into account by the straight-light propagation models used for reconstruction. These artifacts hinder high-resolution imaging with OPT. In this work we show that, by using a multiview imagin  ...[more]

Similar Datasets

| S-EPMC5685650 | biostudies-literature
| S-EPMC4105320 | biostudies-literature
| S-EPMC4386612 | biostudies-literature
| S-EPMC3826518 | biostudies-literature
| S-EPMC4374707 | biostudies-literature
| S-EPMC3959838 | biostudies-other
| S-EPMC7316014 | biostudies-literature
| S-EPMC6075701 | biostudies-literature