Unknown

Dataset Information

0

Bedload Transport Monitoring in Alpine Rivers: Variability in Swiss Plate Geophone Response.


ABSTRACT: Acoustic sensors are increasingly used to measure bedload transport in Alpine streams, notably the Swiss plate geophone (SPG) system. An impact experiment using artificial weights is developed in this paper to assess the variability in individual plate response and to evaluate the extent to which calibration coefficients can be transferred from calibrated plates to non-calibrated plates at a given measuring site and/or to other measuring sites. Results of the experiment over 43 plates at four measuring sites have notably shown (a) that the maximum amplitude (V) recorded by individual plates tends to evolve as a power law function of the impact energy (J), with an exponent slightly larger than 1, for all the plates at all measuring sites; (b) that there is a substantial propagation of energy across plates that should be taken into account for a better understanding of the signal response; (c) that the response of individual plates is in most cases consistent, which suggests that calibration coefficients are comparable within and in between measuring sites, but site-specific and plate-specific variabilities in signal response have to be considered for a detailed comparison.

SUBMITTER: Antoniazza G 

PROVIDER: S-EPMC7436244 | biostudies-literature | 2020 Jul

REPOSITORIES: biostudies-literature

altmetric image

Publications

Bedload Transport Monitoring in Alpine Rivers: Variability in Swiss Plate Geophone Response.

Antoniazza Gilles G   Nicollier Tobias T   Wyss Carlos R CR   Boss Stefan S   Rickenmann Dieter D  

Sensors (Basel, Switzerland) 20200722 15


Acoustic sensors are increasingly used to measure bedload transport in Alpine streams, notably the Swiss plate geophone (SPG) system. An impact experiment using artificial weights is developed in this paper to assess the variability in individual plate response and to evaluate the extent to which calibration coefficients can be transferred from calibrated plates to non-calibrated plates at a given measuring site and/or to other measuring sites. Results of the experiment over 43 plates at four me  ...[more]

Similar Datasets

| S-EPMC8360013 | biostudies-literature
| S-EPMC7840655 | biostudies-literature
| S-EPMC4931009 | biostudies-literature
| S-EPMC10642794 | biostudies-literature
| S-EPMC9541479 | biostudies-literature
| S-EPMC6377629 | biostudies-literature
| S-EPMC7552603 | biostudies-literature
| S-EPMC3340304 | biostudies-literature
| S-EPMC4435963 | biostudies-literature
| S-EPMC4551254 | biostudies-literature