Unknown

Dataset Information

0

Comparison of McGrath, Pentax, and Macintosh laryngoscope in normal and cervical immobilized manikin by novices: a randomized crossover trial.


ABSTRACT: BACKGROUND:The aim of this study was to compare tracheal intubation performance regarding the time to intubation, glottic view, difficulty, and dental click, by novices using McGrath videolaryngoscope (VL), Pentax Airway Scope (AWS) and Macintosh laryngoscope in normal and cervical immobilized manikin models. METHODS:Thirty-five anesthesia nurses without previous intubation experience were recruited. Participants performed endotracheal intubation in a manikin model at two simulated neck positions (normal and fixed neck via cervical immobilization), using three different devices three times each. Performance parameters included intubation time, success rate of intubation, Cormack Lehane laryngoscope grading, dental click, and subjective difficulty score. RESULTS:Intubation time and success rate during first attempt were not significantly different between the 3 groups in normal airway manikin. In the cervical immobilized manikin, the intubation time was shorter (p?=?0.012), and the success rate with the first attempt was significantly higher (p?

SUBMITTER: Yi IK 

PROVIDER: S-EPMC7441605 | biostudies-literature | 2020 Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

Comparison of McGrath, Pentax, and Macintosh laryngoscope in normal and cervical immobilized manikin by novices: a randomized crossover trial.

Yi In Kyong IK   Kwak Hyun Jeong HJ   Lee Kyung Cheon KC   Lee Ji Hyea JH   Min Sang Kee SK   Kim Jong Yeop JY  

European journal of medical research 20200820 1


<h4>Background</h4>The aim of this study was to compare tracheal intubation performance regarding the time to intubation, glottic view, difficulty, and dental click, by novices using McGrath videolaryngoscope (VL), Pentax Airway Scope (AWS) and Macintosh laryngoscope in normal and cervical immobilized manikin models.<h4>Methods</h4>Thirty-five anesthesia nurses without previous intubation experience were recruited. Participants performed endotracheal intubation in a manikin model at two simulate  ...[more]

Similar Datasets

| S-EPMC6255773 | biostudies-literature
| S-EPMC5040779 | biostudies-literature
| S-EPMC4748894 | biostudies-literature
| S-EPMC7429469 | biostudies-literature
| S-EPMC6756366 | biostudies-literature
| S-EPMC4616410 | biostudies-literature
| S-EPMC8234758 | biostudies-literature
| S-EPMC5302788 | biostudies-literature
| S-EPMC6717380 | biostudies-literature
| S-EPMC10887893 | biostudies-literature