Ultrasensitive detection of cadmium ions using a microcantilever-based piezoresistive sensor for groundwater.


ABSTRACT: This paper proposes the selective and ultrasensitive detection of Cd(II) ions using a cysteamine-functionalized microcantilever-based sensor with cross-linked ??-glyceraldehyde (DL-GC). The detection time for various laboratory-based techniques is generally 12-24 hours. The experiments were performed to create self-assembled monolayers (SAMs) of cysteamine cross-linked with ??-glyceraldehyde on the microcantilever surface to selectively capture the targeted Cd(II). The proposed portable microfluidic platform is able to achieve the detection in 20-23 min with a limit of detection (LOD) of 0.56 ng (2.78 pM), which perfectly describes its excellent performance over other reported techniques. Many researchers used nanoparticle-based sensors for the detection of heavy metal ions, but daily increasing usage and commercialization of nanoparticles are rapidly expanding their deleterious effect on human health and the environment. The proposed technique uses a blend of thin-film and microcantilever (micro-electromechanical systems) technology, which mitigate the disadvantages of the nanoparticle approaches, for the selective detection of Cd(II) with a LOD below the WHO limit of 3 ?g/L.

SUBMITTER: Rotake D 

PROVIDER: S-EPMC7445416 | biostudies-literature | 2020

REPOSITORIES: biostudies-literature

altmetric image

Publications

Ultrasensitive detection of cadmium ions using a microcantilever-based piezoresistive sensor for groundwater.

Rotake Dinesh D   Darji Anand A   Kale Nitin N  

Beilstein journal of nanotechnology 20200818


This paper proposes the selective and ultrasensitive detection of Cd(II) ions using a cysteamine-functionalized microcantilever-based sensor with cross-linked ᴅʟ-glyceraldehyde (DL-GC). The detection time for various laboratory-based techniques is generally 12-24 hours. The experiments were performed to create self-assembled monolayers (SAMs) of cysteamine cross-linked with ᴅʟ-glyceraldehyde on the microcantilever surface to selectively capture the targeted Cd(II). The proposed portable microflu  ...[more]

Similar Datasets

| S-EPMC9138971 | biostudies-literature
| S-EPMC5157177 | biostudies-other
| S-EPMC4654508 | biostudies-literature
| S-EPMC8433135 | biostudies-literature
| S-EPMC6489696 | biostudies-literature
| S-EPMC9100864 | biostudies-literature
| S-EPMC4855224 | biostudies-literature
| S-EPMC6318270 | biostudies-literature
| S-EPMC8308118 | biostudies-literature
| S-EPMC4754691 | biostudies-literature