Unknown

Dataset Information

0

Polyp Detection Rate as a Surrogate for Adenoma and Sessile Serrated Adenoma/Polyp Detection Rates.


ABSTRACT: Introduction:Quality measures for colonoscopy such as adenoma detection rate (ADR) have been proposed to be surveilled for ensuring minimum standards. However, its direct measurement is time consuming and often neglected. Extrapolating ADR and other quality measures from polyp detection rate (PDR) can be a pragmatic alternative. Objective:To determine quotients for estimating ADR and sessile serrated adenoma/polyp detection rate (SSA/P-DR) from PDR in an Australian cohort. Methods:Consecutive adult patient colonoscopies during a 1-year period were retrospectively assessed in a single Australian tertiary endoscopy center. Adenoma detection quotient (ADQ) and SSA/P detection quotient (SSA/P-DQ) were defined as the division of ADR and SSA/P-DR by PDR, respectively. The primary outcome was the number of procedures to achieve a stable cumulative ADQ and SSA/P-DQ. Secondary outcomes included evaluation of ADQ and SSA/P-DQ in different subsets. Results:In total, 2,657 colonoscopies were performed by 15 endoscopists in 2016. The ADR, SSA/P-DR, and PDR found were 32.2, 6.7, and 47.3%, respectively. The ADQ and SSA/P-DQ values found were 0.68 and 0.14, respectively. After approximately 500 procedures, both ADQ and SSA/P-DQ became stable. Interclass correlation coefficient (ICC) for the prediction of ADR from ADQ was excellent for all endoscopists that performed >177 procedures in that year (ICC 0.84). Conclusions:ADQ and SSA/P-DQ values were consistent when over 500 procedures were analyzed. ADQ had an excellent correlation with ADR when >177 procedures per endoscopist were evaluated.

SUBMITTER: Zorron Cheng Tao Pu L 

PROVIDER: S-EPMC7445665 | biostudies-literature | 2020 Jul

REPOSITORIES: biostudies-literature

altmetric image

Publications


<h4>Introduction</h4>Quality measures for colonoscopy such as adenoma detection rate (ADR) have been proposed to be surveilled for ensuring minimum standards. However, its direct measurement is time consuming and often neglected. Extrapolating ADR and other quality measures from polyp detection rate (PDR) can be a pragmatic alternative.<h4>Objective</h4>To determine quotients for estimating ADR and sessile serrated adenoma/polyp detection rate (SSA/P-DR) from PDR in an Australian cohort.<h4>Meth  ...[more]

Similar Datasets

| S-EPMC6970553 | biostudies-literature
| S-EPMC7558296 | biostudies-literature
| S-EPMC7710617 | biostudies-literature
| S-EPMC6893174 | biostudies-literature
| S-EPMC3649993 | biostudies-literature
| S-EPMC6160341 | biostudies-literature