Unknown

Dataset Information

0

The design of an "H" joystick for closed reduction and its application in segmental and comminuted femoral shaft fractures: an innovative technique.


ABSTRACT: BACKGROUND:Closed reduction and locked intramedullary nailing has become a common surgical method in the treatment of femoral shaft fractures. Overlap and rotation displacements can usually be corrected through the use of an orthopedic traction table. However, lateral displacement and angulation persist. METHODS:In this paper, we describe a joystick that can be used in the closed reduction of a fracture. It can correct lateral displacement and angulation, and has the advantage of multi-direction reduction. The device described in this paper includes two parallel horizontal joysticks, one vertical main joystick and four assistant rods. Moreover, there are many specific spacing holes in the two parallel horizontal joysticks and a groove structure in the vertical main joystick. When the main "H" joystick is pressed, it can adjust lateral displacements and angulation because of the lever principle. The distance between parallel horizontal joysticks and assistant rods can be adjusted to the fracture position and body mass index of different patients. RESULTS:The study participants consisted of 11 males and 5 females with a mean age of 31.0 years. All participants had good closed reduction and achieved bony union without any complications such as infection, nerve injury, non-union, malunion, and limb length discrepancy. By using an "H" joystick, closed femoral shaft fracture reduction and locked intramedullary nailing becomes simpler and faster. CONCLUSION:Based on the use of this instrument, we can easily and conveniently obtain the correct reduction situation, which leads to better surgical results. This device can be applied in the reduction of clinical femoral fractures and gradually extended to the reduction of other fractures.

SUBMITTER: Jia Z 

PROVIDER: S-EPMC7449011 | biostudies-literature | 2020 Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

The design of an "H" joystick for closed reduction and its application in segmental and comminuted femoral shaft fractures: an innovative technique.

Jia Zhaofeng Z   Wang Shijin S   Xiao Tinghui T   Jiang Wei W   Zhou Tianjian T   Liu Qisong Q   Li Guangheng G   Hu Xinjia X  

Journal of orthopaedic surgery and research 20200826 1


<h4>Background</h4>Closed reduction and locked intramedullary nailing has become a common surgical method in the treatment of femoral shaft fractures. Overlap and rotation displacements can usually be corrected through the use of an orthopedic traction table. However, lateral displacement and angulation persist.<h4>Methods</h4>In this paper, we describe a joystick that can be used in the closed reduction of a fracture. It can correct lateral displacement and angulation, and has the advantage of  ...[more]

Similar Datasets

| S-EPMC5530786 | biostudies-other
| S-EPMC5580418 | biostudies-literature
| S-EPMC2267537 | biostudies-other
| S-EPMC7488305 | biostudies-literature
| S-EPMC5899094 | biostudies-literature
| S-EPMC7818597 | biostudies-literature
| S-EPMC2266637 | biostudies-other
| S-EPMC7966639 | biostudies-literature
| S-EPMC6723720 | biostudies-literature
| S-EPMC3052430 | biostudies-literature