Unknown

Dataset Information

0

Optimized polymer-based glucose release in microtiter plates for small-scale E. coli fed-batch cultivations.


ABSTRACT: Background:Small-scale cultivation vessels, which allow fed-batch operation mode, become more and more important for fast and reliable early process development. Recently, the polymer-based feeding system was introduced to allow fed-batch conditions in microtiter plates. Maximum glucose release rates of 0.35?mg/h per well (48-well-plate) at 37?°C can be achieved with these plates, depending on the media properties. The fed-batch cultivation of fluorescent protein-expressing E. coli at oxygen transfer rate levels of 5?mmol/L/h proved to be superior compared to simple batch cultivations. However, literature suggests that higher glucose release rates than achieved with the currently available fed-batch microtiter plate are beneficial, especially for fast-growing microorganisms. During the fed-batch phase of the cultivation, a resulting oxygen transfer rate level of 28?mmol/L/h should be achieved. Results:Customization of the polymer matrix enabled a considerable increase in the glucose release rate of more than 250% to up to 0.90?mg/h per well. Therefore, the molecular weight of the prepolymer and the addition of a hydrophilic PDMS-PEG copolymer allowed for the individual adjustment of a targeted glucose release rate. The newly developed polymer matrix was additionally invariant to medium properties like the osmotic concentration or the pH-value. The glucose release rate of the optimized matrix was constant in various synthetic and complex media. Fed-batch cultivations of E. coli in microtiter plates with the optimized matrix revealed elevated oxygen transfer rates during the fed-batch phase of approximately 28?mmol/L/h. However, these increased glucose release rates resulted in a prolonged initial batch phase and oxygen limitations. The newly developed polymer-based feeding system provides options to manufacture individual feed rates in a range from 0.24-0.90?mg/h per well. Conclusions:The optimized polymer-based fed-batch microtiter plate allows higher reproducibility of fed-batch experiments since cultivation media properties have almost no influence on the release rate. The adjustment of individual feeding rates in a wide range supports the early process development for slow, average and fast-growing microorganisms in microtiter plates. The study underlines the importance of a detailed understanding of the metabolic behavior (through online monitoring techniques) to identify optimal feed rates.

SUBMITTER: Keil T 

PROVIDER: S-EPMC7457294 | biostudies-literature | 2020

REPOSITORIES: biostudies-literature

altmetric image

Publications

Optimized polymer-based glucose release in microtiter plates for small-scale <i>E. coli</i> fed-batch cultivations.

Keil Timm T   Dittrich Barbara B   Lattermann Clemens C   Büchs Jochen J  

Journal of biological engineering 20200827


<h4>Background</h4>Small-scale cultivation vessels, which allow fed-batch operation mode, become more and more important for fast and reliable early process development. Recently, the polymer-based feeding system was introduced to allow fed-batch conditions in microtiter plates. Maximum glucose release rates of 0.35 mg/h per well (48-well-plate) at 37 °C can be achieved with these plates, depending on the media properties. The fed-batch cultivation of fluorescent protein-expressing <i>E. coli</i  ...[more]

Similar Datasets

| S-EPMC6800402 | biostudies-literature
| S-EPMC8397650 | biostudies-literature
2021-01-25 | PXD018439 | Pride
| S-EPMC3100327 | biostudies-literature