Concurrent heart rate validity of wearable technology devices during trail running.


ABSTRACT: Validation of heart rate responses in wearable technology devices is generally composed of laboratory-based protocols that are steady state in nature and as a result, high accuracy measures are returned. However, there is a need to understand device validity in applied settings that include varied intensities of exercise. The purpose was to determine concurrent heart rate validity during trail running. Twenty-one healthy participants volunteered (female n = 10, [mean (SD)]: age = 31 [11] years, height = 173.0 [7] cm, mass = 75.6 [13] kg). Participants were outfitted with wearable technology devices (Garmin Fenix 5 wristwatch, Jabra Elite Sport earbuds, Motiv ring, Scosche Rhythm+ forearm band, Suunto Spartan Sport watch with accompanying chest strap) and completed a self-paced 3.22 km trail run while concurrently wearing a criterion heart rate strap (Polar H7 heart rate monitor). The trail runs were out-and-back with the first 1.61 km in an uphill direction, and the 1.61 return being downhill in nature. Validity was determined through three methods: Mean Absolute Percent Error (MAPE), Bland-Altman Limits of Agreement (LOA), and Lin's Concordance Coefficient (rC). Validity measures overall are as follows: Garmin Fenix 5 (MAPE = 13%, LOA = -32 to 162, rC = 0.32), Jabra Elite Sport (MAPE = 23%, LOA = -464 to 503, rC = 0.38), Motiv ring (MAPE = 16%, LOA = -52 to 96, rC = 0.29), Scosche Rhythm+ (MAPE = 6%, LOA = -114 to 120, rC = 0.79), Suunto Spartan Sport (MAPE = 2%, LOA = -62 to 61, rC = 0.96). All photoplethysmography-based (PPG) devices displayed poor heart rate agreement during variable intensity trail running. Until technological advances occur in PPG-based devices allowing for acceptable agreement, heart rate in outdoor environments should be obtained using an ECG-based chest strap that can be connected to a wristwatch or other comparable receiver.

SUBMITTER: Navalta JW 

PROVIDER: S-EPMC7458324 | biostudies-literature | 2020

REPOSITORIES: biostudies-literature

altmetric image

Publications

Concurrent heart rate validity of wearable technology devices during trail running.

Navalta James W JW   Montes Jeffrey J   Bodell Nathaniel G NG   Salatto Robert W RW   Manning Jacob W JW   DeBeliso Mark M  

PloS one 20200831 8


Validation of heart rate responses in wearable technology devices is generally composed of laboratory-based protocols that are steady state in nature and as a result, high accuracy measures are returned. However, there is a need to understand device validity in applied settings that include varied intensities of exercise. The purpose was to determine concurrent heart rate validity during trail running. Twenty-one healthy participants volunteered (female n = 10, [mean (SD)]: age = 31 [11] years,  ...[more]

Similar Datasets

| S-EPMC7509623 | biostudies-literature
| S-EPMC9671438 | biostudies-literature
| S-EPMC7913967 | biostudies-literature
| S-EPMC9474518 | biostudies-literature
| S-EPMC10017947 | biostudies-literature
| S-EPMC7146569 | biostudies-literature
| S-EPMC6736776 | biostudies-literature
| S-EPMC8566120 | biostudies-literature
| S-EPMC10793034 | biostudies-literature
| S-EPMC7199133 | biostudies-literature