Unknown

Dataset Information

0

Photoplethysmographic Time-Domain Heart Rate Measurement Algorithm for Resource-Constrained Wearable Devices and its Implementation.


ABSTRACT: This paper presents an algorithm for the measurement of the human heart rate, using photoplethysmography (PPG), i.e., the detection of the light at the skin surface. The signal from the PPG sensor is processed in time-domain; the peaks in the preprocessed and conditioned PPG waveform are detected by using a peak detection algorithm to find the heart rate in real time. Apart from the PPG sensor, the accelerometer is also used to detect body movement and to indicate the moments in time, for which the PPG waveform can be unreliable. This paper describes in detail the signal conditioning path and the modified algorithm, and it also gives an example of implementation in a resource-constrained wrist-wearable device. The algorithm was evaluated by using the publicly available PPG-DaLia dataset containing samples collected during real-life activities with a PPG sensor and accelerometer and with an ECG signal as ground truth. The quality of the results is comparable to the other algorithms from the literature, while the required hardware resources are lower, which can be significant for wearable applications.

SUBMITTER: Wojcikowski M 

PROVIDER: S-EPMC7146569 | biostudies-literature | 2020 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

Photoplethysmographic Time-Domain Heart Rate Measurement Algorithm for Resource-Constrained Wearable Devices and its Implementation.

Wójcikowski Marek M   Pankiewicz Bogdan B  

Sensors (Basel, Switzerland) 20200323 6


This paper presents an algorithm for the measurement of the human heart rate, using photoplethysmography (PPG), i.e., the detection of the light at the skin surface. The signal from the PPG sensor is processed in time-domain; the peaks in the preprocessed and conditioned PPG waveform are detected by using a peak detection algorithm to find the heart rate in real time. Apart from the PPG sensor, the accelerometer is also used to detect body movement and to indicate the moments in time, for which  ...[more]

Similar Datasets

| S-EPMC8443549 | biostudies-literature
| S-EPMC6736776 | biostudies-literature
| S-EPMC6340913 | biostudies-literature
| S-EPMC7867180 | biostudies-literature
| S-EPMC10316692 | biostudies-literature
| S-EPMC7458324 | biostudies-literature
| S-EPMC6923760 | biostudies-literature
| S-EPMC7913967 | biostudies-literature
| S-EPMC9671438 | biostudies-literature
| S-EPMC9379796 | biostudies-literature