Unknown

Dataset Information

0

Contamination of Zearalenone from China in 2019 by a Visual and Digitized Immunochromatographic Assay.


ABSTRACT: Zearalenone (ZEN) is a prevalent mycotoxin that needs intensive monitoring. A semi-quantitative and quantitative immunochromatographic assay (ICA) was assembled for investigating ZEN contamination in 187 samples of cereal and their products from China in 2019. The semi-quantitative detection model had a limit of detection (LOD) of 0.50 ng/mL with visual judgment and could be completely inhibited within 5 min at 3.0 ng/mL ZEN. The quantitative detection model had a lower LOD of 0.25 ng/mL, and ZEN could be accurately and digitally detected from 0.25-4.0 ng/mL. The ICA method had a high sensitivity, specificity, and accuracy for on-site ZEN detection. For investigation of the authentic samples, the ZEN-positive rate was 62.6%, and the ZEN-positive levels ranged from 2.7 to 867.0 ng/g, with an average ZEN-positive level being 85.0 ng/g. Of the ZEN-positive samples, 6.0% exceeded the values of the limit levels. The ZEN-positive samples were confirmed to be highly correlated using LC-MS/MS (R2 = 0.9794). This study could provide an efficiency and accuracy approach for ZEN in order to achieve visual and digitized on-site investigation. This significant information about the ZEN contamination levels might contribute to monitoring mycotoxin occurrence and for ensuring food safety.

SUBMITTER: Hong X 

PROVIDER: S-EPMC7472730 | biostudies-literature | 2020 Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

Contamination of Zearalenone from China in 2019 by a Visual and Digitized Immunochromatographic Assay.

Hong Xia X   Mao Yuhao Y   Yang Chuqin C   Liu Zhenjiang Z   Li Ming M   Du Daolin D  

Toxins 20200814 8


Zearalenone (ZEN) is a prevalent mycotoxin that needs intensive monitoring. A semi-quantitative and quantitative immunochromatographic assay (ICA) was assembled for investigating ZEN contamination in 187 samples of cereal and their products from China in 2019. The semi-quantitative detection model had a limit of detection (LOD) of 0.50 ng/mL with visual judgment and could be completely inhibited within 5 min at 3.0 ng/mL ZEN. The quantitative detection model had a lower LOD of 0.25 ng/mL, and ZE  ...[more]

Similar Datasets

| S-EPMC5425148 | biostudies-literature
| S-EPMC6238117 | biostudies-literature
| S-EPMC4915992 | biostudies-literature
| S-EPMC5848188 | biostudies-literature
| S-EPMC3813722 | biostudies-literature
| S-EPMC2832444 | biostudies-literature
| S-EPMC8234612 | biostudies-literature
| S-EPMC7176116 | biostudies-literature
| S-EPMC7143912 | biostudies-literature
| S-EPMC9720522 | biostudies-literature