Unknown

Dataset Information

0

Optimization of nitrogen and carbon removal with simultaneous partial nitrification, anammox and denitrification in membrane bioreactor.


ABSTRACT: In this study, a membrane bioreactor (MBR) was used to achieve both nitrogen and carbon removal by a simultaneous partial nitrification, anammox and denitrification (SNAD) process. During the entire experiment, the intermittent aeration (non-aerobic time : aeration time, min min-1) cycle was controlled by a time-controlled switch, and the aeration rate was controlled by a gas flowmeter, and the optimal operating parameters as determined by response surface methodology (RSM) were a C/N value of 1.16, a DO value of 0.84 mg l-1 and an aerobic time (T ae) of 15.75 min. Under these conditions, the SNAD process achieved efficient and stable nitrogen and carbon removal; the total inorganic nitrogen removal efficiency and chemical oxygen demand removal efficiency were 92.31% and 95.67%, respectively. With the formation of granular sludge, the membrane fouling rate decreased significantly from 35.0 Pa h-1 at SNAD start-up to 19.9 Pa h-1 during stable operation. Fluorescence in situ hybrid analyses confirmed the structural characteristics and the relative ratio of aerobic ammonia-oxidizing bacteria, anaerobic ammonia-oxidizing bacteria and denitrifying bacteria in the SNAD system.

SUBMITTER: Zhang K 

PROVIDER: S-EPMC7540762 | biostudies-literature | 2020 Sep

REPOSITORIES: biostudies-literature

altmetric image

Publications

Optimization of nitrogen and carbon removal with simultaneous partial nitrification, anammox and denitrification in membrane bioreactor.

Zhang Kai K   Wang Zhaozhao Z   Sun Mengxia M   Liang Dongbo D   Hou Liangang L   Zhang Jing J   Wang Xiujie X   Li Jun J  

Royal Society open science 20200909 9


In this study, a membrane bioreactor (MBR) was used to achieve both nitrogen and carbon removal by a simultaneous partial nitrification, anammox and denitrification (SNAD) process. During the entire experiment, the intermittent aeration (non-aerobic time : aeration time, min min<sup>-1</sup>) cycle was controlled by a time-controlled switch, and the aeration rate was controlled by a gas flowmeter, and the optimal operating parameters as determined by response surface methodology (RSM) were a C/N  ...[more]

Similar Datasets

| S-EPMC9076434 | biostudies-literature
| S-EPMC10020585 | biostudies-literature
| PRJNA665601 | ENA
| PRJNA982692 | ENA
| PRJEB63097 | ENA
| S-EPMC6113234 | biostudies-literature
2022-12-09 | PXD038710 |
| PRJNA722874 | ENA
| S-EPMC4899737 | biostudies-literature
| S-EPMC9083452 | biostudies-literature