Unknown

Dataset Information

0

Single-Cell Electroporation with Real-Time Impedance Assessment Using a Constriction Microchannel.


ABSTRACT: The electroporation system can serve as a tool for the intracellular delivery of foreign cargos. However, this technique is presently limited by the inaccurate electric field applied to the single cells and lack of a real-time electroporation metrics subsystem. Here, we reported a microfluidic system for precise and rapid single-cell electroporation and simultaneous impedance monitoring in a constriction microchannel. When single cells (A549) were continuously passing through the constriction microchannel, a localized high electric field was applied on the cell membrane, which resulted in highly efficient (up to 96.6%) electroporation. During a single cell entering the constriction channel, an abrupt impedance drop was noticed and demonstrated to be correlated with the occurrence of electroporation. Besides, while the cell was moving in the constriction channel, the stabilized impedance showed the capability to quantify the electroporation extent. The correspondence of the impedance variation and electroporation was validated by the intracellular delivery of the fluorescence indicator (propidium iodide). Based on the obtained results, this system is capable of precise control of electroporation and real-time, label-free impedance assessment, providing a potential tool for intracellular delivery and other biomedical applications.

SUBMITTER: Ye Y 

PROVIDER: S-EPMC7570009 | biostudies-literature | 2020 Sep

REPOSITORIES: biostudies-literature

altmetric image

Publications

Single-Cell Electroporation with Real-Time Impedance Assessment Using a Constriction Microchannel.

Ye Yifei Y   Luan Xiaofeng X   Zhang Lingqian L   Zhao Wenjie W   Cheng Jie J   Li Mingxiao M   Zhao Yang Y   Huang Chengjun C  

Micromachines 20200916 9


The electroporation system can serve as a tool for the intracellular delivery of foreign cargos. However, this technique is presently limited by the inaccurate electric field applied to the single cells and lack of a real-time electroporation metrics subsystem. Here, we reported a microfluidic system for precise and rapid single-cell electroporation and simultaneous impedance monitoring in a constriction microchannel. When single cells (A549) were continuously passing through the constriction mi  ...[more]

Similar Datasets

| S-EPMC8433324 | biostudies-literature
| S-EPMC6843681 | biostudies-literature
| S-EPMC4432390 | biostudies-literature
| S-EPMC3805499 | biostudies-literature
| S-EPMC6457513 | biostudies-literature
| S-SCDT-10_1038-S44318-024-00183-5 | biostudies-other
| S-EPMC9853957 | biostudies-literature
| S-EPMC3535553 | biostudies-literature
| S-EPMC8069235 | biostudies-literature
| S-EPMC6627833 | biostudies-literature