Physiological and quantitative CT-scan characterization of COVID-19 and typical ARDS: a matched cohort study.


ABSTRACT:

Purpose

To investigate whether COVID-19-ARDS differs from all-cause ARDS.

Methods

Thirty-two consecutive, mechanically ventilated COVID-19-ARDS patients were compared to two historical ARDS sub-populations 1:1 matched for PaO2/FiO2 or for compliance of the respiratory system. Gas exchange, hemodynamics and respiratory mechanics were recorded at 5 and 15 cmH2O PEEP. CT scan variables were measured at 5 cmH2O PEEP.

Results

Anthropometric characteristics were similar in COVID-19-ARDS, PaO2/FiO2-matched-ARDS and Compliance-matched-ARDS. The PaO2/FiO2-matched-ARDS and COVID-19-ARDS populations (both with PaO2/FiO2 106?±?59 mmHg) had different respiratory system compliances (Crs) (39?±?11 vs 49.9?±?15.4 ml/cmH2O, p?=?0.03). The Compliance-matched-ARDS and COVID-19-ARDS had similar Crs (50.1?±?15.7 and 49.9?±?15.4 ml/cmH2O, respectively) but significantly lower PaO2/FiO2 for the same Crs (160?±?62 vs 106.5?±?59.6 mmHg, p?2/FiO2-matched-ARDS 930?±?644 ml, COVID-19-ARDS 1670?±?791 ml and Compliance-matched-ARDS 1301?±?627 ml, p?2/FiO2-matched-ARDS and Compliance-matched-ARDS (p?2O improved oxygenation in all groups. However, while lung mechanics and dead space improved in PaO2/FiO2-matched-ARDS, suggesting recruitment as primary mechanism, they remained unmodified or worsened in COVID-19-ARDS and Compliance-matched-ARDS, suggesting lower recruitment potential and/or blood flow redistribution.

Conclusions

COVID-19-ARDS is a subset of ARDS characterized overall by higher compliance and lung gas volume for a given PaO2/FiO2, at least when considered within the timeframe of our study.

SUBMITTER: Chiumello D 

PROVIDER: S-EPMC7577365 | biostudies-literature | 2020 Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications


<h4>Purpose</h4>To investigate whether COVID-19-ARDS differs from all-cause ARDS.<h4>Methods</h4>Thirty-two consecutive, mechanically ventilated COVID-19-ARDS patients were compared to two historical ARDS sub-populations 1:1 matched for PaO<sub>2</sub>/FiO<sub>2</sub> or for compliance of the respiratory system. Gas exchange, hemodynamics and respiratory mechanics were recorded at 5 and 15 cmH<sub>2</sub>O PEEP. CT scan variables were measured at 5 cmH<sub>2</sub>O PEEP.<h4>Results</h4>Anthropom  ...[more]

Similar Datasets

| S-EPMC4219337 | biostudies-literature
| S-EPMC8775048 | biostudies-literature
| PRJEB25493 | ENA
| S-EPMC7290545 | biostudies-literature
| S-EPMC7010890 | biostudies-literature
| S-EPMC9469157 | biostudies-literature
| S-EPMC7848247 | biostudies-literature
| S-EPMC8316646 | biostudies-literature
| S-EPMC3318949 | biostudies-literature
| S-EPMC8085195 | biostudies-literature