Expandable and implantable bioelectronic complex for analyzing and regulating real-time activity of the urinary bladder.


ABSTRACT: Underactive bladder or detrusor underactivity (DUA), that is, not being able to micturate, has received less attention with little research and remains unknown or limited on pathological causes and treatments as opposed to overactive bladder, although the syndrome may pose a risk of urinary infections or life-threatening kidney damage. Here, we present an integrated expandable electronic and optoelectronic complex that behaves as a single body with the elastic, time-dynamic urinary bladder with substantial volume changes up to ~300%. The system configuration of the electronics validated by the theoretical model allows conformal, seamless integration onto the urinary bladder without a glue or suture, enabling precise monitoring with various electrical components for real-time status and efficient optogenetic manipulation for urination at the desired time. In vivo experiments using diabetic DUA models demonstrate the possibility for practical uses of high-fidelity electronics in clinical trials associated with the bladder and other elastic organs.

SUBMITTER: Jang TM 

PROVIDER: S-EPMC7673729 | biostudies-literature | 2020 Nov

REPOSITORIES: biostudies-literature

altmetric image

Publications

Expandable and implantable bioelectronic complex for analyzing and regulating real-time activity of the urinary bladder.

Jang Tae-Min TM   Lee Joong Hoon JH   Zhou Honglei H   Joo Jaesun J   Lim Bong Hee BH   Cheng Huanyu H   Kim Soo Hyun SH   Kang Il-Suk IS   Lee Kyu-Sung KS   Park Eunkyoung E   Hwang Suk-Won SW  

Science advances 20201111 46


Underactive bladder or detrusor underactivity (DUA), that is, not being able to micturate, has received less attention with little research and remains unknown or limited on pathological causes and treatments as opposed to overactive bladder, although the syndrome may pose a risk of urinary infections or life-threatening kidney damage. Here, we present an integrated expandable electronic and optoelectronic complex that behaves as a single body with the elastic, time-dynamic urinary bladder with  ...[more]

Similar Datasets

2012-05-01 | GSE35795 | GEO
2012-04-30 | E-GEOD-35795 | biostudies-arrayexpress
2008-12-25 | GSE14096 | GEO
| 2582039 | ecrin-mdr-crc
| S-EPMC9420334 | biostudies-literature
| S-EPMC7412512 | biostudies-literature
| S-EPMC6755526 | biostudies-other
| S-EPMC8104272 | biostudies-literature
| S-EPMC6475664 | biostudies-literature
| S-EPMC5155583 | biostudies-literature