Minimum Information for Reporting on the Comet Assay (MIRCA): recommendations for describing comet assay procedures and results.


ABSTRACT: The comet assay is a widely used test for the detection of DNA damage and repair activity. However, there are interlaboratory differences in reported levels of baseline and induced damage in the same experimental systems. These differences may be attributed to protocol differences, although it is difficult to identify the relevant conditions because detailed comet assay procedures are not always published. Here, we present a Consensus Statement for the Minimum Information for Reporting Comet Assay (MIRCA) providing recommendations for describing comet assay conditions and results. These recommendations differentiate between 'desirable' and 'essential' information: 'essential' information refers to the precise details that are necessary to assess the quality of the experimental work, whereas 'desirable' information relates to technical issues that might be encountered when repeating the experiments. Adherence to MIRCA recommendations should ensure that comet assay results can be easily interpreted and independently verified by other researchers.

SUBMITTER: Moller P 

PROVIDER: S-EPMC7688437 | biostudies-literature | 2020 Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications

Minimum Information for Reporting on the Comet Assay (MIRCA): recommendations for describing comet assay procedures and results.

Møller Peter P   Azqueta Amaya A   Boutet-Robinet Elisa E   Koppen Gudrun G   Bonassi Stefano S   Milić Mirta M   Gajski Goran G   Costa Solange S   Teixeira João Paulo JP   Costa Pereira Cristiana C   Dusinska Maria M   Godschalk Roger R   Brunborg Gunnar G   Gutzkow Kristine B KB   Giovannelli Lisa L   Cooke Marcus S MS   Richling Elke E   Laffon Blanca B   Valdiglesias Vanessa V   Basaran Nursen N   Del Bo' Cristian C   Zegura Bojana B   Novak Matjaz M   Stopper Helga H   Vodicka Pavel P   Vodenkova Sona S   de Andrade Vanessa Moraes VM   Sramkova Monika M   Gabelova Alena A   Collins Andrew A   Langie Sabine A S SAS  

Nature protocols 20201026 12


The comet assay is a widely used test for the detection of DNA damage and repair activity. However, there are interlaboratory differences in reported levels of baseline and induced damage in the same experimental systems. These differences may be attributed to protocol differences, although it is difficult to identify the relevant conditions because detailed comet assay procedures are not always published. Here, we present a Consensus Statement for the Minimum Information for Reporting Comet Ass  ...[more]

Similar Datasets

| S-EPMC6123892 | biostudies-other
| S-EPMC6150419 | biostudies-literature
| S-EPMC5774126 | biostudies-literature
| S-EPMC8647919 | biostudies-literature
| S-EPMC7405976 | biostudies-literature
| S-EPMC5031183 | biostudies-literature
| S-EPMC4674382 | biostudies-literature
| S-EPMC2667151 | biostudies-literature
| S-EPMC6887010 | biostudies-literature
| S-EPMC7763633 | biostudies-literature