Use of implantable meshes for augmented rotator cuff repair: a systematic review and meta-analysis.


ABSTRACT: Objective: To appraise studies reporting on clinical effectiveness and safety of surgical meshes used to augment rotator cuff repairs (RCRs).

Design: Systematic review and meta-analysis.

Data sources: MEDLINE, Embase and Cochrane databases were searched between April 2006 and April 2020.

Eligibility criteria: All studies evaluating adults (?18 years) undergoing RCR were considered. There were no language restrictions.

Data extraction and synthesis: Screening, data extraction and quality appraisal were conducted by two independent reviewers. Meta-analysis was conducted using a random-effects models if ?2 comparative studies reported the same outcome measure. Risk of bias assessment was undertaken for randomised (RoB2, Cochrane) and comparative studies (ROBINS-I, Cochrane).

Results: We included 60 studies, consisting of 7 randomised controlled trials, 13 observational comparative studies and 40 observational case series. All comparative studies reported on shoulder-specific functional outcome scores, 18 on the radiographic occurrence of re-tear and 14 on pain score metrics. All studies contained some risk of bias.Compared with non-augmented repair, a small improvement in shoulder-specific function or pain scores was observed for synthetic patches with a mean improvement of 6.7 points on the University of California Los Angles (UCLA) shoulder score (95% CI 0.1 to 13.4) and 0.46 point reduction on the Visual Analogue Scale (95% CI -0.74 to -0.17), respectively. A reduced likelihood of radiologically observed re-tear was observed for synthetic (risk ratio (RR) 0.41, 95% CI 0.27 to 0.61) and allograft (RR 0.34, 95% CI 0.18 to 0.65) patches. A total of 49 studies reported on the occurrence of complications. Slightly higher crude complication rates were observed following patch-augmented repair (2.1%) than standard repair (1.6%).

Conclusions: While several studies suggest a decreased failure rate and small improvements in shoulder function and pain following augmented RCR, a paucity of rigorous clinical evaluation, for both effectiveness and safety, prevents firm recommendations.

Prospero registration number: CRD42017057908.

SUBMITTER: Baldwin M 

PROVIDER: S-EPMC7722806 | biostudies-literature | 2020 Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications

Use of implantable meshes for augmented rotator cuff repair: a systematic review and meta-analysis.

Baldwin Mathew M   Nagra N S NS   Greenall Gemma G   Carr Andrew J AJ   Beard David D   Rees J L JL   Rangan Amar A   Merritt Naomi N   Dritsaki Melina M   Hopewell Sally S   Cook Jonathan Alistair JA  

BMJ open 20201207 12


<h4>Objective</h4>To appraise studies reporting on clinical effectiveness and safety of surgical meshes used to augment rotator cuff repairs (RCRs).<h4>Design</h4>Systematic review and meta-analysis.<h4>Data sources</h4>MEDLINE, Embase and Cochrane databases were searched between April 2006 and April 2020.<h4>Eligibility criteria</h4>All studies evaluating adults (≥18 years) undergoing RCR were considered. There were no language restrictions.<h4>Data extraction and synthesis</h4>Screening, data  ...[more]