Unknown

Dataset Information

0

Quantitative accuracy of virtual non-contrast images derived from spectral detector computed tomography: an abdominal phantom study.


ABSTRACT: Dual-energy CT allows for the reconstruction of virtual non-contrast (VNC) images. VNC images have the potential to replace true non-contrast scans in various clinical applications. This study investigated the quantitative accuracy of VNC attenuation images considering different parameters for acquisition and reconstruction. An abdomen phantom with 7 different tissue types (different combinations of 3 base materials and 5 iodine concentrations) was scanned using a spectral detector CT (SDCT). Different phantom sizes (S, M, L), volume computed tomography dose indices (CTDIvol 10, 15, 20 mGy), kernel settings (soft, standard, sharp), and denoising levels (low, medium, high) were tested. Conventional and VNC images were reconstructed and analyzed based on regions of interest (ROI). Mean and standard deviation were recorded and differences in attenuation between corresponding base materials and VNC was calculated (VNCerror). Statistic analysis included ANOVA, Wilcoxon test and multivariate regression analysis. Overall, the VNCerror was -?1.4?±?6.1 HU. While radiation dose, kernel setting, and denoising level did not influence VNCerror significantly, phantom size, iodine content and base material had a significant effect (e.g. S vs. M: -?1.2?±?4.9 HU vs. -?2.1?±?6.0 HU; 0.0 mg/ml vs. 5.0 mg/ml: -?4.0?±?3.5 HU vs. 5.1?±?5.0 HU and 35-HU-base vs. 54-HU-base: -?3.5?±?4.4 HU vs. 0.7?±?6.5; all p???0.05). The overall accuracy of VNC images from SDCT is high and independent from dose, kernel, and denoising settings; however, shows a dependency on patient size, base material, and iodine content; particularly the latter results in small, yet, noticeable differences in VNC attenuation.

SUBMITTER: Holz JA 

PROVIDER: S-EPMC7725817 | biostudies-literature | 2020 Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications

Quantitative accuracy of virtual non-contrast images derived from spectral detector computed tomography: an abdominal phantom study.

Holz Jasmin A JA   Alkadhi Hatem H   Laukamp Kai R KR   Lennartz Simon S   Heneweer Carola C   Püsken Michael M   Persigehl Thorsten T   Maintz David D   Große Hokamp Nils N  

Scientific reports 20201209 1


Dual-energy CT allows for the reconstruction of virtual non-contrast (VNC) images. VNC images have the potential to replace true non-contrast scans in various clinical applications. This study investigated the quantitative accuracy of VNC attenuation images considering different parameters for acquisition and reconstruction. An abdomen phantom with 7 different tissue types (different combinations of 3 base materials and 5 iodine concentrations) was scanned using a spectral detector CT (SDCT). Di  ...[more]

Similar Datasets

| S-EPMC8043945 | biostudies-literature
| S-EPMC5544796 | biostudies-other
| S-EPMC6505638 | biostudies-literature
| S-EPMC5570320 | biostudies-literature
| S-EPMC6283621 | biostudies-literature
| S-EPMC7511018 | biostudies-literature
| S-EPMC6400385 | biostudies-literature
| S-EPMC7997324 | biostudies-literature
| S-EPMC5528944 | biostudies-other
| S-EPMC10017605 | biostudies-literature