Manual Muscle Testing-Force Profiles and Their Reproducibility.


ABSTRACT: The manual muscle test (MMT) is a flexible diagnostic tool, which is used in many disciplines, applied in several ways. The main problem is the subjectivity of the test. The MMT in the version of a "break test" depends on the tester's force rise and the patient's ability to resist the applied force. As a first step, the investigation of the reproducibility of the testers' force profile is required for valid application. The study examined the force profiles of n = 29 testers (n = 9 experiences (Exp), n = 8 little experienced (LitExp), n = 12 beginners (Beg)). The testers performed 10 MMTs according to the test of hip flexors, but against a fixed leg to exclude the patient's reaction. A handheld device recorded the temporal course of the applied force. The results show significant differences between Exp and Beg concerning the starting force (padj = 0.029), the ratio of starting to maximum force (padj = 0.005) and the normalized mean Euclidean distances between the 10 trials (padj = 0.015). The slope is significantly higher in Exp vs. LitExp (p = 0.006) and Beg (p = 0.005). The results also indicate that experienced testers show inter-tester differences and partly even a low intra-tester reproducibility. This highlights the necessity of an objective MMT-assessment. Furthermore, an agreement on a standardized force profile is required. A suggestion for this is given.

SUBMITTER: Bittmann FN 

PROVIDER: S-EPMC7759939 | biostudies-literature | 2020 Nov

REPOSITORIES: biostudies-literature

altmetric image

Publications

Manual Muscle Testing-Force Profiles and Their Reproducibility.

Bittmann Frank N FN   Dech Silas S   Aehle Markus M   Schaefer Laura V LV  

Diagnostics (Basel, Switzerland) 20201125 12


The manual muscle test (MMT) is a flexible diagnostic tool, which is used in many disciplines, applied in several ways. The main problem is the subjectivity of the test. The MMT in the version of a "break test" depends on the tester's force rise and the patient's ability to resist the applied force. As a first step, the investigation of the reproducibility of the testers' force profile is required for valid application. The study examined the force profiles of <i>n</i> = 29 testers (<i>n</i> = 9  ...[more]

Similar Datasets

| S-EPMC7951326 | biostudies-literature
| S-EPMC3973819 | biostudies-literature
| S-EPMC9175444 | biostudies-literature
| S-EPMC2891143 | biostudies-literature
| S-EPMC4057053 | biostudies-literature
| S-EPMC7918832 | biostudies-literature
| S-EPMC10941330 | biostudies-literature
| S-EPMC5875759 | biostudies-literature
| S-EPMC5470739 | biostudies-literature
| S-EPMC4375060 | biostudies-literature