Long-Term Stability Analysis of 3D and 2D/3D Hybrid Perovskite Solar Cells Using Electrochemical Impedance Spectroscopy.


ABSTRACT: Despite the remarkable progress in perovskite solar cells (PSCs), their instability and rapid degradation over time still restrict their commercialization. A 2D capping layer has been proved to overcome the stability issues; however, an in-depth understanding of the complex degradation processes over a prolonged time at PSC interfaces is crucial for improving their stability. In the current work, we investigated the stability of a triple cation 3D ([(FA0.83MA0.17)Cs0.05]Pb(I0.83Br0.17)3) and 2D/3D PSC fabricated by a layer-by-layer deposition technique (PEAI-based 2D layer over triple cation 3D perovskite) using a state-of-art characterization technique: electrochemical impedance spectroscopy (EIS). A long-term stability test over 24 months was performed on the 3D and 2D/3D PSCs with an initial PCE of 18.87% and 20.21%, respectively, to suggest a more practical scenario. The current-voltage (J-V) and EIS results showed degradation in both the solar cell types; however, a slower degradation rate was observed in 2D/3D PSCs. Finally, the quantitative analysis of the key EIS parameters affected by the degradation in 3D and 2D/3D PSCs were discussed.

SUBMITTER: Abdulrahim SM 

PROVIDER: S-EPMC7763814 | biostudies-literature | 2020 Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications

Long-Term Stability Analysis of 3D and 2D/3D Hybrid Perovskite Solar Cells Using Electrochemical Impedance Spectroscopy.

Abdulrahim Sumayya M SM   Ahmad Zubair Z   Bhadra Jolly J   Al-Thani Noora Jabor NJ  

Molecules (Basel, Switzerland) 20201208 24


Despite the remarkable progress in perovskite solar cells (PSCs), their instability and rapid degradation over time still restrict their commercialization. A 2D capping layer has been proved to overcome the stability issues; however, an in-depth understanding of the complex degradation processes over a prolonged time at PSC interfaces is crucial for improving their stability. In the current work, we investigated the stability of a triple cation 3D ([(FA<sub>0.83</sub>MA<sub>0.17</sub>)Cs<sub>0.0  ...[more]

Similar Datasets

| S-EPMC5461484 | biostudies-literature
| S-EPMC8224444 | biostudies-literature
| S-EPMC7539205 | biostudies-literature
| S-EPMC6240600 | biostudies-literature
| S-EPMC6070510 | biostudies-literature
| S-EPMC10226519 | biostudies-literature
| S-EPMC5694650 | biostudies-literature
| S-EPMC6952449 | biostudies-literature
| S-EPMC6555633 | biostudies-literature
| S-EPMC5956977 | biostudies-literature