Unknown

Dataset Information

0

Analysis of Conductance Probes for Two-Phase Flow and Holdup Applications.


ABSTRACT: In this paper we perform an analysis of the conductance probes used in two-phase flow applications especially for two-phase flow tomography of annular flow, to measure the waves produced in the interface with different boundary conditions without perturbing the flow, and in addition we examine the holdup applications as measuring the average void fraction in a given region. The method used to obtain the detector conductance between the electrodes is to solve analytically the generalized Laplace equation in 3D with the boundary conditions of the problem, and then to obtain the average potential difference between the detector electrodes. Then, dividing the current intensity circulating between the emitter and the receiver electrodes by the average potential difference yields the probe conductance, which depends on the geometric and physical characteristics of the measured system and the probe. This conductance is then non-dimensionalized by dividing by the conductance of the pipe full of water. In this way a set of analytical expression have been obtained for the conductance of two-plate sensors with different geometries and locations. We have performed an exhaustive comparison of the results obtained using the equations deduced in this paper with the experimental data from several authors in different cases with very good agreement. In some cases when the distribution of bubbles is not homogeneous, we have explored the different alternatives of the effective medium theory (EMT) in terms of the self-consistent EMT and the non-consistent EMT.

SUBMITTER: Munoz-Cobo JL 

PROVIDER: S-EPMC7763996 | biostudies-literature | 2020 Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications

Analysis of Conductance Probes for Two-Phase Flow and Holdup Applications.

Muñoz-Cobo José-Luis JL   Rivera Yago Y   Berna Cesar C   Escrivá Alberto A  

Sensors (Basel, Switzerland) 20201209 24


In this paper we perform an analysis of the conductance probes used in two-phase flow applications especially for two-phase flow tomography of annular flow, to measure the waves produced in the interface with different boundary conditions without perturbing the flow, and in addition we examine the holdup applications as measuring the average void fraction in a given region. The method used to obtain the detector conductance between the electrodes is to solve analytically the generalized Laplace  ...[more]

Similar Datasets

| S-EPMC4500946 | biostudies-literature
| S-EPMC4278694 | biostudies-literature
| S-EPMC5529577 | biostudies-literature
| S-EPMC6314586 | biostudies-literature
| S-EPMC8110123 | biostudies-literature
| S-EPMC9789109 | biostudies-literature
| S-EPMC8160198 | biostudies-literature
| S-EPMC6955111 | biostudies-literature
| S-EPMC3927471 | biostudies-literature
| S-EPMC4735800 | biostudies-other