Imaging Subthreshold Voltage Oscillation With Cellular Resolution in the Inferior Olive in vitro.


ABSTRACT: Voltage imaging with cellular resolution in mammalian brain slices is still a challenging task. Here, we describe and validate a method for delivery of the voltage-sensitive dye ANNINE-6plus (A6+) into tissue for voltage imaging that results in higher signal-to-noise ratio (SNR) than conventional bath application methods. The not fully dissolved dye was injected into the inferior olive (IO) 0, 1, or 7 days prior to acute slice preparation using stereotactic surgery. We find that the voltage imaging improves after an extended incubation period in vivo in terms of labeled volume, homogeneous neuropil labeling with saliently labeled somata, and SNR. Preparing acute slices 7 days after the dye injection, the SNR is high enough to allow single-trial recording of IO subthreshold oscillations using wide-field (network-level) as well as high-magnification (single-cell level) voltage imaging with a CMOS camera. This method is easily adaptable to other brain regions where genetically-encoded voltage sensors are prohibitively difficult to use and where an ultrafast, pure electrochromic sensor, like A6+, is required. Due to the long-lasting staining demonstrated here, the method can be combined, for example, with deep-brain imaging using implantable GRIN lenses.

SUBMITTER: Dorgans K 

PROVIDER: S-EPMC7767970 | biostudies-literature | 2020

REPOSITORIES: biostudies-literature

altmetric image

Publications

Imaging Subthreshold Voltage Oscillation With Cellular Resolution in the Inferior Olive <i>in vitro</i>.

Dorgans Kevin K   Kuhn Bernd B   Uusisaari Marylka Yoe MY  

Frontiers in cellular neuroscience 20201214


Voltage imaging with cellular resolution in mammalian brain slices is still a challenging task. Here, we describe and validate a method for delivery of the voltage-sensitive dye ANNINE-6plus (A6+) into tissue for voltage imaging that results in higher signal-to-noise ratio (SNR) than conventional bath application methods. The not fully dissolved dye was injected into the inferior olive (IO) 0, 1, or 7 days prior to acute slice preparation using stereotactic surgery. We find that the voltage imag  ...[more]

Similar Datasets

| S-EPMC2000380 | biostudies-literature
| S-EPMC7012604 | biostudies-literature
| S-EPMC3390386 | biostudies-other
| S-EPMC7839749 | biostudies-literature
| S-EPMC8095336 | biostudies-literature
| S-EPMC6538185 | biostudies-literature
| S-EPMC2544464 | biostudies-literature
| S-EPMC7456658 | biostudies-literature
| S-EPMC2777250 | biostudies-literature
| S-EPMC6872567 | biostudies-literature