Ontology highlight
ABSTRACT: Background
Real-Time Reverse-Transcription Polymerase Chain Reaction (RT-PCR) is currently the only recommended diagnostic method for SARS-CoV-2. However, rapid immunoassays for SARS-CoV-2 antigen could significantly reduce the COVID-19 burden currently weighing on laboratories around the world.Methods
We evaluated the performance of two rapid fluorescence immunoassays (FIAs), SOFIA SARS Antigen FIA (Quidel Corporation, San Diego, CA, USA) and STANDARD F COVID-19 Ag FIA (SD Biosensor Inc., Gyeonggi-do, Republic of Korea), which use an automated reader. The study used 64 RT-PCR characterized clinical samples (32 positive; 32 negative), which consisted of nasopharyngeal swabs in universal transport medium.Results
Of the 32 positive specimens, all from patients within 5 days of symptom onset, the Quidel and SD Biosensor assays detected 30 (93.8%) and 29 (90.6%) samples, respectively. Among the 27 samples with high viral loads (Ct ? 25), the two tests had a sensitivity of 100%. Specificity was 96.9% for both kits.Conclusion
The high performance of the evaluated FIAs indicates a potential use as rapid and PCR-independent tools for COVID-19 diagnosis in early stages of infection. The excellent sensitivity to detect cases with viral loads above ~106 copies/mL (Ct values ? 25), the estimated threshold of contagiousness, suggests that the assays might serve to rapidly identify infective individuals.
SUBMITTER: Porte L
PROVIDER: S-EPMC7827970 | biostudies-literature | 2021
REPOSITORIES: biostudies-literature
PeerJ 20210121
<h4>Background</h4>Real-Time Reverse-Transcription Polymerase Chain Reaction (RT-PCR) is currently the only recommended diagnostic method for SARS-CoV-2. However, rapid immunoassays for SARS-CoV-2 antigen could significantly reduce the COVID-19 burden currently weighing on laboratories around the world.<h4>Methods</h4>We evaluated the performance of two rapid fluorescence immunoassays (FIAs), SOFIA SARS Antigen FIA (Quidel Corporation, San Diego, CA, USA) and STANDARD F COVID-19 Ag FIA (SD Biose ...[more]