Unknown

Dataset Information

0

The Direct Observation of Lymphaticovenular Anastomosis Patency with Photoacoustic Lymphangiography.


ABSTRACT: It is difficult to evaluate the postoperative patency of lymphaticovenular anastomosis, but this evaluation is essential for determining surgical results. When using the current standard modality, near-infrared fluorescent lymphography, it is difficult to observe patency if the anastomotic point is veiled by dermal backflow. In this study, we used a new photoacoustic imaging device, PAI-05, to check the patency of anastomosis. We performed photoacoustic lymphangiography after lymphaticovenular anastomosis surgery. By digitally subtracting the superficial area, we can examine an area deeper than the dermal backflow, which is not visible by near-infrared fluorescent lymphography. The connection between the lymphatic vessel and the venule observed in the image is an indication of the patency of anastomosis. However, in a non-patent anastomosed site, the lymphatic vessel has a gap that separates it from the venule at the anastomosed site. Although photoacoustic lymphangiography cannot be used to visualize the lymphatic vessels that are not contrasted by indocyanine green, the resulting high-resolution images and clear anastomosis evaluation afforded by it will contribute to the development of future lymphedema treatments.

SUBMITTER: Suzuki Y 

PROVIDER: S-EPMC7858285 | biostudies-literature | 2021 Jan

REPOSITORIES: biostudies-literature

altmetric image

Publications

The Direct Observation of Lymphaticovenular Anastomosis Patency with Photoacoustic Lymphangiography.

Suzuki Yushi Y   Kajita Hiroki H   Kono Hikaru H   Okabe Keisuke K   Sakuma Hisashi H   Imanishi Nobuaki N   Aiso Sadakazu S   Kishi Kazuo K  

Plastic and reconstructive surgery. Global open 20210128 1


It is difficult to evaluate the postoperative patency of lymphaticovenular anastomosis, but this evaluation is essential for determining surgical results. When using the current standard modality, near-infrared fluorescent lymphography, it is difficult to observe patency if the anastomotic point is veiled by dermal backflow. In this study, we used a new photoacoustic imaging device, PAI-05, to check the patency of anastomosis. We performed photoacoustic lymphangiography after lymphaticovenular a  ...[more]

Similar Datasets

| S-EPMC3607574 | biostudies-literature
| S-EPMC5543202 | biostudies-other
| S-EPMC7225471 | biostudies-literature
| S-EPMC6962462 | biostudies-literature
| S-EPMC9532031 | biostudies-literature
| S-EPMC6985198 | biostudies-literature
| S-EPMC6821566 | biostudies-literature
| S-EPMC6018121 | biostudies-literature
| S-EPMC2438383 | biostudies-literature