Unknown

Dataset Information

0

A Pilot Study with Randomised Controlled Design Comparing TiZr Alloy Dental Implants to Ti Implants.


ABSTRACT:

Objectives

Evidence on the clinical performance of recently introduced dental implants in titanium-zirconium alloy is sparse. The aim of the present pilot study with randomized controlled design is to compare changes in supporting structures around dental titanium-zirconium alloy implants to commercially pure titanium implants.

Material and methods

The present material includes consecutive patients referred to a specialist clinic in Sweden. Two patient groups treated with dental implants in two different materials - titanium (Ti) and titanium-zirconium (TiZr) - were defined after block randomisation for smoking. In total, 40 implants installed in 21 patients were available for one-year follow-up. Marginal bone level, soft tissue height and width of keratinised mucosa were registered at baseline and at one-year follow-up.

Results

At implant level, the test group (TiZr) yielded significant marginal bone loss (P < 0.001) after one year. Additionally, marginal bone loss after one year was significantly higher for TiZr implants (P < 0.001) as compared to traditional Ti implants. Soft tissue dimensions were stable throughout the evaluation time for both implant materials.

Conclusions

One-year results indicate more pronounced initial marginal bone loss for dental implants in titanium-zirconium alloy as compared to implants made of commercially pure titanium.

SUBMITTER: Hultin K 

PROVIDER: S-EPMC7875101 | biostudies-literature | 2020 Oct-Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications

A Pilot Study with Randomised Controlled Design Comparing TiZr Alloy Dental Implants to Ti Implants.

Hultin Kristina K   Eriksson Annelie A   Backe Christina C   Johansson Ulf U   Bougas Kostas K  

Journal of oral & maxillofacial research 20201001 4


<h4>Objectives</h4>Evidence on the clinical performance of recently introduced dental implants in titanium-zirconium alloy is sparse. The aim of the present pilot study with randomized controlled design is to compare changes in supporting structures around dental titanium-zirconium alloy implants to commercially pure titanium implants.<h4>Material and methods</h4>The present material includes consecutive patients referred to a specialist clinic in Sweden. Two patient groups treated with dental i  ...[more]

Similar Datasets

| S-EPMC7505912 | biostudies-literature
| S-EPMC4394505 | biostudies-literature
| S-EPMC4945923 | biostudies-literature
| S-EPMC9303227 | biostudies-literature
| S-EPMC4256038 | biostudies-literature
| S-EPMC5118711 | biostudies-literature
| S-EPMC6993989 | biostudies-literature
| S-EPMC7817818 | biostudies-literature
| S-EPMC7084739 | biostudies-literature
| S-EPMC3773636 | biostudies-literature