Unknown

Dataset Information

0

A self-referenced in-situ arrival time monitor for X-ray free-electron lasers.


ABSTRACT: We present a novel, highly versatile, and self-referenced arrival time monitor for measuring the femtosecond time delay between a hard X-ray pulse from a free-electron laser and an optical laser pulse, measured directly on the same sample used for pump-probe experiments. Two chirped and picosecond long optical supercontinuum pulses traverse the sample with a mutually fixed time delay of 970 fs, while a femtosecond X-ray pulse arrives at an instant in between both pulses. Behind the sample the supercontinuum pulses are temporally overlapped to yield near-perfect destructive interference in the absence of the X-ray pulse. Stimulation of the sample with an X-ray pulse delivers non-zero contributions at certain optical wavelengths, which serve as a measure of the relative arrival time of the X-ray pulse with an accuracy of better than 25 fs. We find an excellent agreement of our monitor with the existing timing diagnostics at the SACLA XFEL with a Pearson correlation value of 0.98. We demonstrate a high sensitivity to measure X-ray pulses with pulse energies as low as 30 [Formula: see text]J. Using a free-flowing liquid jet as interaction sample ensures the full replacement of the sample volume for each X-ray/optical event, thus enabling its utility even at MHz repetition rate XFEL sources.

SUBMITTER: Diez M 

PROVIDER: S-EPMC7878505 | biostudies-literature | 2021 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications


We present a novel, highly versatile, and self-referenced arrival time monitor for measuring the femtosecond time delay between a hard X-ray pulse from a free-electron laser and an optical laser pulse, measured directly on the same sample used for pump-probe experiments. Two chirped and picosecond long optical supercontinuum pulses traverse the sample with a mutually fixed time delay of 970 fs, while a femtosecond X-ray pulse arrives at an instant in between both pulses. Behind the sample the su  ...[more]

Similar Datasets

| S-EPMC10148857 | biostudies-literature
| S-EPMC5178802 | biostudies-literature
| S-EPMC6613120 | biostudies-literature
| S-EPMC10598033 | biostudies-literature
| S-EPMC4260607 | biostudies-literature
| S-EPMC4008696 | biostudies-literature
| S-EPMC7642782 | biostudies-literature
| S-EPMC7088463 | biostudies-literature
| S-EPMC10245879 | biostudies-literature
| S-EPMC10530093 | biostudies-literature