Propensity of aerosol and droplet creation during oculoplastic procedures: A risk assessment with high-speed imaging amidst COVID-19 pandemic.


ABSTRACT:

Purpose

The study uses principles of liquid and gas mechanics to verify and quantify the generation of aerosols in oculoplastic procedures, namely surgery using a scalpel, electrosurgical device, and a mechanized drill.

Methods

Surgical techniques were performed ex vivo using the electrosurgical device, scalpel, and mechanized drill on the muscle and bone of commercially available chicken. The liquid and gas dynamics were observed using a high-speed high-resolution Photron SA5 camera (0.125 to 8 ms temporal resolution, 0.016 to 0.054 mm/pixel spatial resolution) and stroboscopic lighting (Veritas 120 E LED Constellation). The analysis was performed using in-house algorithms and ImageJ software.

Results

The use of a mechanized drill at 35000 rpm and a 3 mm fluted burr generated aerosol with particle size 50 to 550 microns with a spread of 1.8 m radius. Surgical smoke was generated by an electrosurgical device in both cutting and coagulation modes. Dispersion of the smoke could be controlled significantly by the use of suction, mean smoke spread ratio being 0.065 without suction and 0.002 with use of suction within 2 cm.

Conclusion

The quantification of the aerosol generation will help surgeons take practical decisions in their surgical techniques in the pandemic era.

SUBMITTER: Gupta R 

PROVIDER: S-EPMC7942117 | biostudies-literature | 2021 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

Propensity of aerosol and droplet creation during oculoplastic procedures: A risk assessment with high-speed imaging amidst COVID-19 pandemic.

Gupta Roshmi R   Pandey Khushboo K   Thomas Rwituja R   Basu Saptarshi S   Shetty Bhujang B   Shetty Rohit R   Roy Abhijit Sinha AS  

Indian journal of ophthalmology 20210301 3


<h4>Purpose</h4>The study uses principles of liquid and gas mechanics to verify and quantify the generation of aerosols in oculoplastic procedures, namely surgery using a scalpel, electrosurgical device, and a mechanized drill.<h4>Methods</h4>Surgical techniques were performed ex vivo using the electrosurgical device, scalpel, and mechanized drill on the muscle and bone of commercially available chicken. The liquid and gas dynamics were observed using a high-speed high-resolution Photron SA5 cam  ...[more]

Similar Datasets

| S-EPMC7251363 | biostudies-literature
| S-EPMC7287440 | biostudies-literature
| S-EPMC7560802 | biostudies-literature
| S-EPMC9616072 | biostudies-literature
| S-EPMC7729578 | biostudies-literature
| S-EPMC9113070 | biostudies-literature
| S-EPMC8415696 | biostudies-literature
| S-EPMC8242633 | biostudies-literature
| S-EPMC10511466 | biostudies-literature
| S-EPMC10562079 | biostudies-literature