Difference in Moxibustion-Induced Microcirculatory Responses between the Heart and Lung Meridians Assessed by Laser Doppler Flowmetry.


ABSTRACT:

Objective

By comparing the differences in microcirculatory responses of the heart and lung meridians induced by moxibustion on these two meridians, respectively, this study aimed to investigate the specificity for site-to-site association on body surface between different meridians.

Methods

Eighty healthy adults were enrolled and divided into the lung meridian intervention group and heart meridian intervention group in a ratio of 1 : 1. Three-channel laser Doppler flowmetry was used to monitor microcirculatory responses for the heart and lung meridians. Primary outcome was change of blood perfusion units (PU) of three measurement sites along the two meridians.

Results

In the lung meridian intervention group, following moxibustion performed at LU5 of the lung meridian, PU in the distal site of the lung meridian increased significantly. By contrast, the PU of HT3 in the heart meridian, which was nearest to the moxibustion site, did not change significantly. PU in the distal site of the heart meridian declined. Meanwhile, significant difference in PU change was detected between the distal site of the lung meridian and the other two control sites of the heart meridians during moxibustion and postmoxibustion. Alternatively, similar to the results of the lung meridian intervention group, the specificity of microcirculatory response between the heart and lung meridians was observed in the heart meridian intervention group.

Conclusions

For the heart and lung meridians, the effect of moxibustion-induced microcirculatory response may be more related to meridian routes than the specific distance between two sites located at different meridians, thereby supporting possible specificity for site-to-site association on the body surface between these two meridians. Nevertheless, given that only two meridians and limited measurement sites were compared, all current findings are not sufficiently robust. Further research should be conducted to investigate more meridians and measurement sites.

SUBMITTER: Jiang Y 

PROVIDER: S-EPMC8032512 | biostudies-literature |

REPOSITORIES: biostudies-literature

Similar Datasets

| S-EPMC4915466 | biostudies-literature
| S-EPMC7493022 | biostudies-literature
| S-EPMC7731012 | biostudies-literature
| S-EPMC7220657 | biostudies-literature
| S-EPMC9136163 | biostudies-literature
| S-EPMC7708681 | biostudies-literature
| S-EPMC2889755 | biostudies-literature
| S-EPMC6221735 | biostudies-literature
| S-EPMC5464709 | biostudies-literature
| S-EPMC9406728 | biostudies-literature