Sentinel lymph node detection in oral cancer: a within-patient comparison between [99mTc]Tc-tilmanocept and [99mTc]Tc-nanocolloid.


ABSTRACT:

Purpose

Sentinel lymph node (SLN) biopsy has proven to reliably stage the clinically negative neck in early-stage oral squamous cell carcinoma (OSCC). [99mTc]Tc-tilmanocept may be of benefit in OSCC with complex lymphatic drainage patterns and close spatial relation to SLNs.

Methods

A prospective within-patient evaluation study was designed to compare [99mTc]Tc-tilmanocept with [99mTc]Tc-nanocolloid for SLN detection. A total of 20 patients with early-stage OSCC were included, who underwent lymphoscintigraphy with both tracers. Both lymphoscintigraphic images of each patient were evaluated for SLN detection and radiotracer distribution at 2-4 h post-injection.

Results

The injection site's remaining radioactivity was significantly lower for [99mTc]Tc-tilmanocept (29.9%), compared with [99mTc]Tc-nanocolloid (60.9%; p < 0.001). Radioactive uptake in SLNs was significantly lower for [99mTc]Tc-tilmanocept (1.95%) compared with [99mTc]Tc-nanocolloid (3.16%; p = 0.010). No significant difference was seen in SLN to injection site ratio in radioactivity between [99mTc]Tc-tilmanocept (0.066) and [99mTc]Tc-nanocolloid (0.054; p = 0.232). A median of 3.0 and 2.5 SLNs were identified with [99mTc]Tc-tilmanocept and [99mTc]Tc-nanocolloid, respectively (p = 0.297). Radioactive uptake in higher echelon nodes was not significantly different between [99mTc]Tc-tilmanocept (0.57%) and [99mTc]Tc-nanocolloid (0.86%) (p = 0.052). A median of 2.0 and 2.5 higher echelon nodes was identified with [99mTc]Tc-tilmanocept and [99mTc]Tc-nanocolloid, respectively (p = 0.083).

Conclusion

[99mTc]Tc-tilmanocept had a higher injection site clearance, but at the same time a lower uptake in the SLN, resulting in an SLN to injection site ratio, which was not significantly different from [99mTc]Tc-nanocolloid. The relatively low-radioactive uptake in SLNs of [99mTc]Tc-tilmanocept may limit intraoperative detection of SLNs, but can be overcome by a higher injection dose.

SUBMITTER: den Toom IJ 

PROVIDER: S-EPMC8036184 | biostudies-literature |

REPOSITORIES: biostudies-literature

Similar Datasets

| S-EPMC10562505 | biostudies-literature
| S-EPMC7555748 | biostudies-literature
| S-EPMC3705144 | biostudies-literature
| S-EPMC8848438 | biostudies-literature
| S-EPMC6134003 | biostudies-literature
| S-EPMC4565859 | biostudies-literature
| S-EPMC6502840 | biostudies-literature
| S-EPMC10296685 | biostudies-literature
| S-EPMC8156251 | biostudies-literature
| S-EPMC6733951 | biostudies-literature