Unknown

Dataset Information

0

Multimodal photoacoustic/ultrasonic imaging system: a promising imaging method for the evaluation of disease activity in rheumatoid arthritis.


ABSTRACT:

Objectives

We aimed to assess the clinical value of multimodal photoacoustic/ultrasound (PA/US) articular imaging scores, a novel imaging method which can reflect the micro-vessels and oxygenation level of inflamed joints of rheumatoid arthritis (RA).

Methods

Seven small joints were examined by the PA/US imaging system. A 0-3 scoring system was used to semi-quantify the PA and power-Doppler (PD) signals, and the sums of PA and PD scores (PA-sum and PD-sum scores) of the seven joints were calculated. The relative oxygen saturation (SO2) values of the inflamed joints were measured and classified into 3 PA+SO2 patterns. The correlations between the PA/US imaging scores and the disease activity scores were assessed.

Results

Thirty-one patients of RA and a total of 217 joints were examined using the PA/US system. The PA-sum had high positive correlations with the standard clinical scores of RA (DAS28 [ESR] ρ = 0.754, DAS28 [CRP] ρ = 0.796, SDAI ρ = 0.836, CDAI ρ = 0.837, p < 0.001), which were superior to the PD-sum (DAS28 [ESR] ρ = 0.651, DAS28 [CRP] ρ = 0.676, SDAI ρ = 0.716, CDAI ρ = 0.709, p < 0.001). For the patients with high PA-sum scores, significant differences between hypoxia and hyperoxia were identified in pain visual analog score (p = 0.020) and patient's global assessment (p = 0.026). The PA+SO2 patterns presented moderate and high correlation with PGA (ρ = 0.477, p = 0.0077) and VAS pain score (ρ = 0.717, p < 0.001).

Conclusion

The PA scores have significant correlations with standard clinical scores for RA, and the PA+SO2 patterns are also related with clinical scores that reflect pain severity. PA may have clinical potential in evaluating RA.

Key points

• Multimodal photoacoustic/ultrasound imaging is a novel method to assess micro-vessels and oxygenation of local lesions. • Significant correlations between multimodal imaging parameters and clinical scores of RA patients were verified. • The multimodal PA/US system can provide objective imaging parameters, including PA scores of micro-vessels and relative SO2 value, as a supplementary to disease activity evaluation.

SUBMITTER: Zhao C 

PROVIDER: S-EPMC8043900 | biostudies-literature |

REPOSITORIES: biostudies-literature

Similar Datasets

| S-EPMC5969522 | biostudies-literature
| S-EPMC10566722 | biostudies-literature
| S-EPMC5670248 | biostudies-literature
| S-EPMC2041835 | biostudies-literature
| S-EPMC3104044 | biostudies-other
| S-EPMC7795655 | biostudies-literature
| S-EPMC7201559 | biostudies-literature
| S-EPMC8624483 | biostudies-literature
| S-EPMC10716268 | biostudies-literature
| S-EPMC7745438 | biostudies-literature