Project description:The objective of this study was to develop a scalable approach for direct comparison of the analytical sensitivities of commercially available SARS-CoV-2 antigen point-of-care tests (AgPOCTs) to rapidly identify poor-performing products. We present a methodology for quick assessment of the sensitivity of SARS-CoV-2 AgPOCTs suitable for quality evaluation of many different products. We established reference samples with high, medium, and low SARS-CoV-2 viral loads along with a SARS-CoV-2 negative control sample. Test samples were used to semi-quantitatively assess the analytical sensitivities of 32 different commercial AgPOCTs in a head-to-head comparison. Among 32 SARS-CoV-2 AgPOCTs tested, we observe sensitivity differences across a broad range of viral loads (9.8 × 108 to 1.8 × 105 SARS-CoV-2 genome copies per ml). 23 AgPOCTs detected the Ct25 test sample (1.6 × 106 copies/ml), while only five tests detected the Ct28 test sample (1.8 × 105 copies/ml). In the low-range of analytical sensitivity, we found three saliva spit tests only delivering positive results for the Ct21 sample (2.7 × 107 copies/ml). Comparison with published data supports our AgPOCT ranking. Importantly, we identified an AgPOCT widely offered, which did not reliably recognize the sample with the highest viral load (Ct16 test sample with 9.8 × 108 copies/ml) leading to serious doubts about its usefulness in SARS-CoV-2 diagnostics. The results show that the rapid sensitivity assessment procedure presented here provides useful estimations on the analytical sensitivities of 32 AgPOCTs and identified a widely-spread AgPOCT with concerningly low sensitivity.
Project description:SARS-CoV-2 viral antigen detection may be an interesting alternative to RT-PCR for the diagnosis of SARS-CoV-2 infection as a less laborious or expensive method but requires validation. This study aimed to compare the performance of the DiaSorin™ LiaisonXL automated quantitative antigen test (QAT) and the AAZ™ rapid antigen test (RAT) to the DiaSorin™ MDX RT-PCR assay. A total of 242 nasopharyngeal samples were tested at La Pitié-Salpêtrière University Hospital (Paris, France). Performances for the detection of variants of SARS-CoV-2 were further investigated. RATs were visually read for qualitative results and band intensity was determined. Overall sensitivity was 63.2% for QAT and 58.6% for RAT. For RT-PCR Ct value 25, sensitivity was 89.8% for both tests. Both tests showed comparable sensitivity for detection of variants. There was a strong relationship between antigen concentration and band positivity. On the same set of samples these tests share similar performances.
Project description:BackgroundAntigen point-of-care tests (AgPOCTs) can accelerate SARS-CoV-2 testing. As some AgPOCTs have become available, interest is growing in their utility and performance. Here we aimed to compare the analytical sensitivity and specificity of seven commercially available AgPOCT devices.MethodsIn a single-centre, laboratory evaluation study, we compared AgPOCT products from seven suppliers: the Abbott Panbio COVID-19 Ag Rapid Test, the RapiGEN BIOCREDIT COVID-19 Ag, the Healgen Coronavirus Ag Rapid Test Cassette (Swab), the Coris BioConcept COVID-19 Ag Respi-Strip, the R-Biopharm RIDA QUICK SARS-CoV-2 Antigen, the nal von minden NADAL COVID-19 Ag Test, and the Roche-SD Biosensor SARS-CoV Rapid Antigen Test. Tests were evaluated on recombinant SARS-CoV-2 nucleoprotein, cultured endemic and emerging coronaviruses, stored respiratory samples with known SARS-CoV-2 viral loads, stored samples from patients with respiratory pathogens other than SARS-CoV-2, and self-sampled swabs from healthy volunteers. We estimated analytical sensitivity in terms of approximate viral concentrations (quantified by real-time RT-PCR) that yielded positive AgPOCT results, and specificity in terms of propensity to generate false-positive results.FindingsIn 138 clinical samples with quantified SARS-CoV-2 viral load, the 95% limit of detection (concentration at which 95% of test results were positive) in six of seven AgPOCT products ranged between 2·07 × 106 and 2·86 × 107 copies per swab, with an outlier (RapiGEN) at 1·57 × 1010 copies per swab. The assays showed no cross-reactivity towards cell culture or tissue culture supernatants containing any of the four endemic human coronaviruses (HCoV‑229E, HCoV‑NL63, HCoV‑OC43, or HCoV‑HKU1) or MERS-CoV, with the exception of the Healgen assay in one repeat test on HCoV-HKU1 supernatant. SARS-CoV was cross-detected by all assays. Cumulative specificities among stored clinical samples with non-SARS-CoV-2 infections (n=100) and self-samples from healthy volunteers (n=35; cumulative sample n=135) ranged between 98·5% (95% CI 94·2-99·7) and 100·0% (97·2-100·0) in five products, with two outliers at 94·8% (89·2-97·7; R-Biopharm) and 88·9% (82·1-93·4; Healgen). False-positive results did not appear to be associated with any specific respiratory pathogen.InterpretationThe sensitivity range of most AgPOCTs overlaps with SARS-CoV-2 viral loads typically observed in the first week of symptoms, which marks the infectious period in most patients. The AgPOCTs with limit of detections that approximate virus concentrations at which patients are infectious might enable shortcuts in decision making in various areas of health care and public health.FundingEU's Horizon 2020 research and innovation programme, German Ministry of Research, German Federal Ministry for Economic Affairs and Energy, German Ministry of Health, and Bill & Melinda Gates Foundation.
Project description:(1) Background: The detection of SARS-CoV-2 RNA in nasopharyngeal samples through real-time reverse transcription-polymerase chain reaction (RT-PCR) is considered the standard gold method for the diagnosis of SARS-CoV-2 infection. Antigen detection (AD) tests are more rapid, less laborious, and less expensive alternatives but still require clinical validation. (2) Methods: This study compared the clinical performance of five AD tests, including four rapid AD (RAD) tests (biotical, Panbio, Healgen, and Roche) and one automated AD test (VITROS). For that purpose, 118 (62.8%) symptomatic patients and 70 (37.2%) asymptomatic subjects were tested, and results were compared to RT-PCR. (3) Results: The performance of the RAD tests was modest and allowed us to identify RT-PCR positive patients with higher viral loads. For Ct values ≤25, the sensitivity ranged from 93.1% (95% CI: 83.3-98.1%) to 96.6% (95% CI: 88.1-99.6%), meaning that some samples with high viral loads were missed. Considering the Ct value proposed by the CDC for contagiousness (i.e., Ct values ≤33) sensitivities ranged from 76.2% (95% CI: 65.4-85.1%) to 88.8% (95% CI: 79.7-94.7%) while the specificity ranged from 96.3% (95% CI: 90.8-99.0%) to 99.1% (95% CI: 95.0-100%). The VITROS automated assay showed a 100% (95% CI: 95.5-100%) sensitivity for Ct values ≤33, and had a specificity of 100% (95% CI: 96.6-100%); (4) Conclusions: Compared to RAD tests, the VITROS assay fully aligned with RT-PCR for Ct values up to 33, which might allow a faster, easier and cheaper identification of SARS-CoV-2 contagious patients.
Project description:The aim of the current study is to perform model calculations on the possible use of SARS-CoV-2-rapid point-of-care tests as mass tests, using the quality criteria extracted from evidence-based research as an example for the Federal Republic of Germany. In addition to illustrating the problem of false positive test results, these calculations are used to examine their possible influence on the 7-day incidence. For a substantial period of time, this parameter formed the decisive basis for decisions on measures to protect the population in the wake of the COVID pandemic, which were taken by the government. Primarily, model calculations were performed for a base model of 1,000,000 SARS-CoV-2-rapid point-of-care tests per week using various sensitivities and specificities reported in the literature, followed by sequential testing of the test positives obtained by a SARS-CoV-2 PCR test. Furthermore, a calculation was performed for an actual maximum model based on self-test contingents by the German Federal Ministry of Health. Assuming a number of 1,000,000 tests per week at a prevalence of 0.5%, a high number of false positive test results, a low positive predictive value, a high negative predictive value, and an increase in the 7-day incidence due to the additional antigen rapid tests of approx. 5/100,000 were obtained. A previous maximum calculation based on contingent numbers for self-tests given by the German Federal Ministry of Health even showed an additional possible influence on the 7-day incidence of 84.6/100,000. The model calculations refer in each case to representative population samples that would have to be drawn if the successive results were comparable which should be given, as far-reaching actions were based on this parameter. The additionally performed SARS-CoV-2-rapid point-of-care tests increase the 7-day incidence in a clear way depending on the number of tests and clearly show their dependence on the respective number of tests. SARS-CoV-2-rapid point-of-care tests as well as the SARS-CoV-2-PCR test method should both be used exclusively in the presence of corresponding respiratory symptoms and not in symptom-free persons.
Project description:The implementation of rapid diagnostic tests (RDTs) may enhance the efficiency of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) testing, as RDTs are widely accessible and easy to use. The aim of this study was to evaluate the performance of a diagnosis strategy based on a combination of antigen and immunoglobulin M (IgM) or immunoglobulin G (IgG) serological RDTs. Plasma and nasopharyngeal samples were collected between 14 March and 11 April 2020 at hospital admission from 45 patients with reverse transcription polymerase chain reaction (RT-PCR) confirmed COVID-19 and 20 negative controls. SARS-CoV-2 antigen (Ag) was assessed in nasopharyngeal swabs using the Coris Respi-Strip. For IgM/IgG detection, SureScreen Diagnostics and Szybio Biotech RDTs were used in addition to laboratory assays (Abbott Alinity i SARS-CoV-2 IgG and Theradiag COVID-19 IgM enzyme-linked immunosorbent assay). Using the Ag RDT, 13 out of 45 (29.0%) specimens tested positive, the sensitivity was 87.0% for cycle threshold (Ct ) values ≤25% and 0% for Ct values greater than 25. IgG detection was associated with high Ct values and the amount of time after the onset of symptoms. The profile of isolated IgM on RDTs was more frequently observed during the first and second week after the onset of symptoms. The combination of Ag and IgM/IgG RDTs enabled the detection of up to 84.0% of COVID-19 confirmed cases at hospital admission. Antigen and antibody-based RDTs showed suboptimal performances when used alone. However when used in combination, they are able to identify most COVID-19 patients admitted in an emergency department.
Project description:Background: SARS-CoV-2 antigen assays offer a rapid mean to diagnose and isolate infected individuals. However, their utility in population-level screening is unknown. Objectives: The performance of two antigen tests in detecting SARS-CoV-2 was assessed among individuals randomly selected in the community. Study Design: A prospective study that performed head-to-head comparison of two SARS-CoV-2 antigen assays. Individuals were recruited during community SARS-CoV-2 screening over 10 working days. Demographic and clinical data were collected. Standard Q COVID-19 Ag test, a point-of-care chromatographic assay, was conducted immediately, and then the sample was transported to the virology laboratory to perform PCR and the LIAISON SARS-CoV-2 Ag chemiluminesence immunoassay. Results: respiratory samples from 991 individuals were collected, and 62 were positive by PCR. Inconclusive PCR results were observed in 19 samples and were excluded. The median age of participants was 40.2 years (IQR 32.3-47.8), and 932 (94%) were males. Most (77.4%) of infections were asymptomatic. The sensitivity and the specificity of the LIAISON assay were 43.3% (95%CI 30.6-56.8) and 99.9% (95%CI 99.3-100). The Standard Q assay had lower sensitivity (30.6%, 95%CI 19.6-43.7) but similar specificity (98.8%, 95%CI, 97.8-99.4). Similarly, the LIAISON assay had higher positive predictive value (96.3%, 95%CI 81-99.9% vs. 63.3%, 95%CI, 43.9-80.1%). Both assays performed better in symptomatic patients and among samples with a low-cycle threshold (Ct < 25). Conclusion: In our setting of random community surveillance, rapid antigen testing of nasopharyngeal swabs by either LIAISON SARS-CoV-2 Ag (DiaSorin) or Standard Q COVID-19 Ag (SD Biosensor) was less sensitive to detecting SARS-CoV-2 than the TaqPath COVID-19 RT-PCR.
Project description:ObjectivesAntigen rapid diagnostic tests (Ag-RDT) have been developed as reliable tools to control the SARS-CoV-2 pandemic. The objective of our study was to evaluate the diagnostic performance of two Ag-RDTs.MethodsWe evaluated CerTest SARS-CoV-2 Ag One Step Card Test and Panbio COVID-19 Ag Rapid Test Device Ag-RDTs. We included 320 nasopharyngeal samples: 150 PCR negative samples to assess the specificity and 170 PCR positive samples to evaluate the sensitivity. We also evaluated their sensitivity according to cycle threshold (Ct) values and the time from the onset of symptoms. Tests were compared using the McNemar's test and agreement was evaluated using the kappa score (k).ResultsBoth Ag-RDTs showed a specificity of 100 %. Overall sensitivity was 53.5 % for CerTest and 60.0 % for Panbio. For samples with Ct≤ 25, sensitivity was 94.0 % for CerTest and 96.4 % for Panbio (p = 0.500). Regarding samples with Ct>25, sensitivity was 14.0 % for CerTest and 24.4 % for Panbio (p = 0.004). Sensitivity for samples within the first 5 days after the onset of symptoms were 84.8 % for CerTest and 91.3 % for Panbio (p = 0.250) and notably decreased for samples taken after the fifth day. Both Ag-RDTs showed an excellent agreement between them (agreement = 96.7 %, k = 0.920). Agreement with PCR was also excellent for high viral load samples (Ct<25) for CerTest (98.0 %, k = 0.954) and Panbio (98.8 %, k = 0.973).ConclusionsCerTest SARS-CoV-2 and Panbio COVID-19 Ag showed excellent performance and agreement results for samples with high viral loads (Ct ≤ 25) or samples taken within the first 5 days after the onset of symptoms.