Project description:PurposeThe objective of this study was to develop a scalable approach for direct comparison of the analytical sensitivities of commercially available SARS-CoV-2 antigen point-of-care tests (AgPOCTs) to rapidly identify poor-performing products.MethodsWe present a methodology for quick assessment of the sensitivity of SARS-CoV-2 AgPOCTs suitable for quality evaluation of many different products. We established reference samples with high, medium, and low SARS-CoV-2 viral loads along with a SARS-CoV-2 negative control sample. Test samples were used to semi-quantitatively assess the analytical sensitivities of 32 different commercial AgPOCTs in a head-to-head comparison.ResultsAmong 32 SARS-CoV-2 AgPOCTs tested, we observe sensitivity differences across a broad range of viral loads (9.8 × 108 to 1.8 × 105 SARS-CoV-2 genome copies per ml). 23 AgPOCTs detected the Ct25 test sample (1.6 × 106 copies/ml), while only five tests detected the Ct28 test sample (1.8 × 105 copies/ml). In the low-range of analytical sensitivity, we found three saliva spit tests only delivering positive results for the Ct21 sample (2.7 × 107 copies/ml). Comparison with published data supports our AgPOCT ranking. Importantly, we identified an AgPOCT widely offered, which did not reliably recognize the sample with the highest viral load (Ct16 test sample with 9.8 × 108 copies/ml) leading to serious doubts about its usefulness in SARS-CoV-2 diagnostics.ConclusionThe results show that the rapid sensitivity assessment procedure presented here provides useful estimations on the analytical sensitivities of 32 AgPOCTs and identified a widely-spread AgPOCT with concerningly low sensitivity.
Project description:SARS-CoV-2 viral antigen detection may be an interesting alternative to RT-PCR for the diagnosis of SARS-CoV-2 infection as a less laborious or expensive method but requires validation. This study aimed to compare the performance of the DiaSorin™ LiaisonXL automated quantitative antigen test (QAT) and the AAZ™ rapid antigen test (RAT) to the DiaSorin™ MDX RT-PCR assay. A total of 242 nasopharyngeal samples were tested at La Pitié-Salpêtrière University Hospital (Paris, France). Performances for the detection of variants of SARS-CoV-2 were further investigated. RATs were visually read for qualitative results and band intensity was determined. Overall sensitivity was 63.2% for QAT and 58.6% for RAT. For RT-PCR Ct value 25, sensitivity was 89.8% for both tests. Both tests showed comparable sensitivity for detection of variants. There was a strong relationship between antigen concentration and band positivity. On the same set of samples these tests share similar performances.
Project description:After three years of the SARS-CoV-2 pandemic, the demand for developing field-deployable point-of-care (PoC) molecular diagnostic tests has increased. Although RT-qPCR is the molecular diagnostic gold standard and is accurate, it is not readily applied to point-of-care testing (POCT). Meanwhile, rapid diagnostic kits have the disadvantage of low sensitivity. Recently, rapid isothermal nucleic acid amplification technology has emerged as an alternative for rapid diagnosis. Here, we developed a rapid SARS-CoV-2 reverse transcription loop-mediated isothermal amplification (RT-LAMP)-lateral flow assay (LFA) kit. This kit includes a Chelex-100/boiling nucleic acid extraction device and a one-step amplification detection apparatus capable of performing the entire process, from RNA extraction to detection, and diagnosing SARS-CoV-2 infection within 40 min without contamination. The detection limits of the rapid SARS-CoV-2 RT-LAMP-LFA kit were 100 plaque-forming units (PFUs) mL-1 and 10-1 PFU mL-1 for RNA samples extracted using the Chelex-100/boiling nucleic acid extraction device and commercial AdvansureTM E3 system, respectively. The sensitivity and specificity of the rapid SARS-CoV-2 RT-LAMP-LFA kit were 97.8% and 100%, respectively. Our SARS-CoV-2 RT-LAMP-LFA kit exhibited high sensitivity and specificity within 40 min without requiring laboratory instruments, suggesting that the kit could be used as a rapid POC molecular diagnostic test for SARS-CoV-2.
Project description:BackgroundAntigen point-of-care tests (AgPOCTs) can accelerate SARS-CoV-2 testing. As some AgPOCTs have become available, interest is growing in their utility and performance. Here we aimed to compare the analytical sensitivity and specificity of seven commercially available AgPOCT devices.MethodsIn a single-centre, laboratory evaluation study, we compared AgPOCT products from seven suppliers: the Abbott Panbio COVID-19 Ag Rapid Test, the RapiGEN BIOCREDIT COVID-19 Ag, the Healgen Coronavirus Ag Rapid Test Cassette (Swab), the Coris BioConcept COVID-19 Ag Respi-Strip, the R-Biopharm RIDA QUICK SARS-CoV-2 Antigen, the nal von minden NADAL COVID-19 Ag Test, and the Roche-SD Biosensor SARS-CoV Rapid Antigen Test. Tests were evaluated on recombinant SARS-CoV-2 nucleoprotein, cultured endemic and emerging coronaviruses, stored respiratory samples with known SARS-CoV-2 viral loads, stored samples from patients with respiratory pathogens other than SARS-CoV-2, and self-sampled swabs from healthy volunteers. We estimated analytical sensitivity in terms of approximate viral concentrations (quantified by real-time RT-PCR) that yielded positive AgPOCT results, and specificity in terms of propensity to generate false-positive results.FindingsIn 138 clinical samples with quantified SARS-CoV-2 viral load, the 95% limit of detection (concentration at which 95% of test results were positive) in six of seven AgPOCT products ranged between 2·07 × 106 and 2·86 × 107 copies per swab, with an outlier (RapiGEN) at 1·57 × 1010 copies per swab. The assays showed no cross-reactivity towards cell culture or tissue culture supernatants containing any of the four endemic human coronaviruses (HCoV‑229E, HCoV‑NL63, HCoV‑OC43, or HCoV‑HKU1) or MERS-CoV, with the exception of the Healgen assay in one repeat test on HCoV-HKU1 supernatant. SARS-CoV was cross-detected by all assays. Cumulative specificities among stored clinical samples with non-SARS-CoV-2 infections (n=100) and self-samples from healthy volunteers (n=35; cumulative sample n=135) ranged between 98·5% (95% CI 94·2-99·7) and 100·0% (97·2-100·0) in five products, with two outliers at 94·8% (89·2-97·7; R-Biopharm) and 88·9% (82·1-93·4; Healgen). False-positive results did not appear to be associated with any specific respiratory pathogen.InterpretationThe sensitivity range of most AgPOCTs overlaps with SARS-CoV-2 viral loads typically observed in the first week of symptoms, which marks the infectious period in most patients. The AgPOCTs with limit of detections that approximate virus concentrations at which patients are infectious might enable shortcuts in decision making in various areas of health care and public health.FundingEU's Horizon 2020 research and innovation programme, German Ministry of Research, German Federal Ministry for Economic Affairs and Energy, German Ministry of Health, and Bill & Melinda Gates Foundation.
Project description:(1) Background: The detection of SARS-CoV-2 RNA in nasopharyngeal samples through real-time reverse transcription-polymerase chain reaction (RT-PCR) is considered the standard gold method for the diagnosis of SARS-CoV-2 infection. Antigen detection (AD) tests are more rapid, less laborious, and less expensive alternatives but still require clinical validation. (2) Methods: This study compared the clinical performance of five AD tests, including four rapid AD (RAD) tests (biotical, Panbio, Healgen, and Roche) and one automated AD test (VITROS). For that purpose, 118 (62.8%) symptomatic patients and 70 (37.2%) asymptomatic subjects were tested, and results were compared to RT-PCR. (3) Results: The performance of the RAD tests was modest and allowed us to identify RT-PCR positive patients with higher viral loads. For Ct values ≤25, the sensitivity ranged from 93.1% (95% CI: 83.3-98.1%) to 96.6% (95% CI: 88.1-99.6%), meaning that some samples with high viral loads were missed. Considering the Ct value proposed by the CDC for contagiousness (i.e., Ct values ≤33) sensitivities ranged from 76.2% (95% CI: 65.4-85.1%) to 88.8% (95% CI: 79.7-94.7%) while the specificity ranged from 96.3% (95% CI: 90.8-99.0%) to 99.1% (95% CI: 95.0-100%). The VITROS automated assay showed a 100% (95% CI: 95.5-100%) sensitivity for Ct values ≤33, and had a specificity of 100% (95% CI: 96.6-100%); (4) Conclusions: Compared to RAD tests, the VITROS assay fully aligned with RT-PCR for Ct values up to 33, which might allow a faster, easier and cheaper identification of SARS-CoV-2 contagious patients.
Project description:The aim of the current study is to perform model calculations on the possible use of SARS-CoV-2-rapid point-of-care tests as mass tests, using the quality criteria extracted from evidence-based research as an example for the Federal Republic of Germany. In addition to illustrating the problem of false positive test results, these calculations are used to examine their possible influence on the 7-day incidence. For a substantial period of time, this parameter formed the decisive basis for decisions on measures to protect the population in the wake of the COVID pandemic, which were taken by the government. Primarily, model calculations were performed for a base model of 1,000,000 SARS-CoV-2-rapid point-of-care tests per week using various sensitivities and specificities reported in the literature, followed by sequential testing of the test positives obtained by a SARS-CoV-2 PCR test. Furthermore, a calculation was performed for an actual maximum model based on self-test contingents by the German Federal Ministry of Health. Assuming a number of 1,000,000 tests per week at a prevalence of 0.5%, a high number of false positive test results, a low positive predictive value, a high negative predictive value, and an increase in the 7-day incidence due to the additional antigen rapid tests of approx. 5/100,000 were obtained. A previous maximum calculation based on contingent numbers for self-tests given by the German Federal Ministry of Health even showed an additional possible influence on the 7-day incidence of 84.6/100,000. The model calculations refer in each case to representative population samples that would have to be drawn if the successive results were comparable which should be given, as far-reaching actions were based on this parameter. The additionally performed SARS-CoV-2-rapid point-of-care tests increase the 7-day incidence in a clear way depending on the number of tests and clearly show their dependence on the respective number of tests. SARS-CoV-2-rapid point-of-care tests as well as the SARS-CoV-2-PCR test method should both be used exclusively in the presence of corresponding respiratory symptoms and not in symptom-free persons.
Project description:ObjectiveThe objective of this study was to evaluate the performance of seven antigen rapid diagnostic tests (Ag RDTs) in a clinical setting to identify those that could be recommended for use in the diagnosis of SARS-CoV-2 infection in Uganda.MethodsThis was a cross-sectional prospective study. Nasopharyngeal swabs were collected consecutively from COVID-19 PCR positive and COVID-19 PCR negative participants at isolation centers and points of entry, and tested with the SARS-CoV-2 Ag RDTs. Test sensitivity and specificity were generated by comparing results against qRT-PCR results (Berlin Protocol) at a cycle threshold (Ct) cut-off of ≤39. Sensitivity was also calculated at Ct cut-offs ≤29 and ≤33.ResultsNone of the Ag RDTs had a sensitivity of ≥80% at Ct cut-off values ≤33 and ≤39. Two kits, Panbio™ COVID-19 Ag and VivaDiag™ SARS-CoV-2 Ag had a sensitivity of ≥80% at a Ct cut-off value of ≤29. Four kits: BIOCREDIT COVID -19 Ag, COVID-19 Ag Respi-Strip, MEDsan® SARS-CoV-2 Antigen Rapid Test and Panbio™ COVID-19 Ag Rapid Test had a specificity of ≥97%.ConclusionsThis evaluation identified one Ag RDT, Panbio™ COVID-19 Ag with a performance at high viral load (Ct value ≤29) reaching that recommended by WHO. This kit was recommended for screening of patients with COVID -19-like symptoms presenting at health facilities.