Ultrasound-assisted of alkali chloride separation using bulk ionic liquid membrane.


ABSTRACT: An ultrasonic-assisted separation of alkali chloride (LiCl, NaCl, and KCl) salts have been carried out using of an hydrophobic ionic liquid membrane (ILM). The ionic liquid 1-butyl-3-methylimidazolium hexafluorophosphate and tributyl phosphate mixture have been used as ILM. An ultrasonic probe with different frequencies (25, 100, and 250) kHz have been applied as source of ultrasound generator with different times of sonication (2, 5, and 10) min in three phases system containing feed, ILM, and receiver in osmotic U-shaped tube. Also, 250, 500, and 1000 ppm of the feed (alkali chloride) concentration have been used to separate. The frequency of 250 kHz with higher sonication time provides optimum condition for separation of LiCl with lower feed concentration. The thermodynamic properties such as density and speed of sound and the related thermodynamic properties have been calculated to optimize ILM composition (xIL = 0.45) for ultrasound-separation.